Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MULTI PACKAGING SOLUTIONS DALLAS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MULTI PACKAGING SOLUTIONS DALLAS, INC in 13465 JUPITER RD, DALLAS, TX 75238 (NAICS 323111). OSHA activity number 343735791.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Multi Packaging Solutions Dallas, INC — free Get an email when a new federal OSHA severe-injury report for Multi Packaging Solutions Dallas, INC is published. One employer, no account, unsubscribe in one click.
Site address
13465 JUPITER RD
City
DALLAS
State
TX
ZIP
75238
Mailing
13465 JUPITER RD, DALLAS, TX 75238
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
6000
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Feb 27, 2019
Abate by
Mar 25, 2019
Penalty
Initial $11,934 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.  c) On January 24, 2019, employee was exposed to a caught in hazard when doing adjustments to the blanker system on the B-3 Die cutter without utilizing energy control procedures  b) On or about January 24, 2019, and times prior employees were exposed to a caught in hazard by not utilizing procedures on the control of potentially hazardous energy when setting up the press 1,3,9,8 in the production area.   c) On or about January 24, 2019, and times prior employees were exposed to a caught in hazard by not utilizing procedures on the control of potentially hazardous energy when setting up or un-jamming the Die Cutter B-1, B-2, B-3 in the production area.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11934

1910.305 B01 I

Other-than-serious 1 instance 3 exposed
Issued
Feb 27, 2019
Abate by
Mar 25, 2019
Penalty
Initial $10,229 · Current $6,137 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.    On January 21, 2019 Employees were exposed to electrical hazard when electrical conductors were not fully encased in the conduit and not protected from abrasions on printing press 1 in the production area.
Recent events (2)
  • — I (O) $6137.4
  • — Z (S) $10229