FENNIMORE, WI ·
OSHA Inspection: ENERGIZER MANUFACTURING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ENERGIZER MANUFACTURING, INC. in 100 RAYOVAC DRIVE, FENNIMORE, WI 53809 (NAICS 335912). OSHA activity number 343735874.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ENERGIZER MANUFACTURING, INC.
- Site address
- 100 RAYOVAC DRIVE
- City
- FENNIMORE
- State
- WI
- ZIP
- 53809
- Mailing
- 100 RAYOVAC DRIVE, FENNIMORE, WI 53809
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335912
- Employees
- 275
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 23, 2019
- Abate by
- Jul 1, 2019
- Penalty
- Initial $10,419 · Current $7,814 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about January 16, 2019 the employer did not ensure that operators utilized procedures to control hazardous energy when adjusting air nozzles on Nail Make Machine number 5, model MJ0520 employer serial number 71225.
Recent events (2)
- · I (S) $7814
- · Z (S) $10419
1910.147 D
- Issued
- May 23, 2019
- Abate by
- Jun 3, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) covered the following elements, however, the actions were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6): On or about January 16, 2019 employees were exposed to machine hazards associated with moving parts and in-going nip points when they engaged clearing jams and adjusting air nozzles on Nail Make Machine number 5, model MJ0520 employer serial number 71225. The employer did not ensure that employees implemented energy control application steps prior to allowing them to servicing the machine. The nail make machine was not shut down or turned off prior to engaging in this servicing activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Energizer Manufacturing, INC.
View Energizer Manufacturing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 335912)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343735874.