Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ENERGIZER MANUFACTURING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENERGIZER MANUFACTURING, INC. in 100 RAYOVAC DRIVE, FENNIMORE, WI 53809 (NAICS 335912). OSHA activity number 343735874.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Energizer Manufacturing, INC. for free Get an email when a new federal OSHA severe-injury report for Energizer Manufacturing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 RAYOVAC DRIVE
City
FENNIMORE
State
WI
ZIP
53809
Mailing
100 RAYOVAC DRIVE, FENNIMORE, WI 53809
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335912
Employees
275
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 9 instances 2 exposed
Issued
May 23, 2019
Abate by
Jul 1, 2019
Penalty
Initial $10,419 · Current $7,814 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about January 16, 2019 the employer did not ensure that operators utilized procedures to control hazardous energy when adjusting air nozzles on Nail Make Machine number 5, model MJ0520 employer serial number 71225.
Recent events (2)
  • · I (S) $7814
  • · Z (S) $10419

1910.147 D

Deleted Serious Gravity 5 8 instances 2 exposed
Issued
May 23, 2019
Abate by
Jun 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d):  The established procedure for the application of energy control (the lockout or tagout procedures) covered the following elements, however, the actions were not done in sequence as required by 29 CFR 1910.147 (d)(1)-(6):  On or about January 16, 2019 employees were exposed to machine hazards associated with moving parts and in-going nip points when they engaged clearing jams and adjusting air nozzles on Nail Make Machine number 5, model MJ0520 employer serial number 71225.  The employer did not ensure that employees implemented energy control application steps prior to allowing them to servicing the machine. The nail make machine was not shut down or turned off prior to engaging in this servicing activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View Energizer Manufacturing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343735874.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.