2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: NOVUM STRUCTURES LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NOVUM STRUCTURES LLC in W126N8585 WESTBROOK CROSSING, MENOMONEE FALLS, WI 53051 (NAICS 332312). OSHA activity number 343739942.

Watch Novum Structures LLC — free Get an email when a new federal OSHA severe-injury report for Novum Structures LLC is published. One employer, no account, unsubscribe in one click.
Site address
W126N8585 WESTBROOK CROSSING
City
MENOMONEE FALLS
State
WI
ZIP
53051
Mailing
W126N8585 WESTBROOK CROSSING, MENOMONEE FALLS, WI 53051
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
60
Ownership type
A

2 citations on file for this inspection.

1910.134 C02 II

Serious Gravity 1 1 instance 8 exposed
Issued
Penalty
Initial $4347.00 · Current $3042.00 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    (a) On April 30, 2019, and on dates prior, the employer did not verify that elements of a written respiratory protection program were in place to ensure that any employee using a respirator voluntarily is medically able to use that respirator. Employees used half-face elastomeric respirators voluntarily without being initially cleared to use a tight-fitting elastomeric respirator by a Physician or Other Licensed Health Care Professional.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $4347

1910.1026 D01

Deleted Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $813.00 · Current $0.00 Reduced

Hazardous substances 0689

29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI):  (a) On April 18, 2019, in the SHOP area located at W126N8585 Westbrook Crossing, Menomonee Falls, WI 53051, where workers were using carbon steel welding wire with varying compositions of chromium, a welder was exposed to hexavalent chromium at an 8-hour time weighted average of 0.192 micrograms per cubic meter while using a chromium containing welding wire. The sample was collected during a 460 minute sampling period and exposure calculations include a zero increment for the 20 minutes not sampled.  The employer is to make this determination in accordance with either paragraph (d)(2), the scheduled monitoring option, or paragraph (d)(3), the performance-oriented option.
Recent events (2)
  • — I (O) $0
  • — Z (O) $813

View NOVUM STRUCTURES LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343739942.