Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: VISTAMATIC, L.L.C.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VISTAMATIC, L.L.C. in 11713 NW 39TH STREET, CORAL SPRINGS, FL 33065 (NAICS 327211). OSHA activity number 343745873.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vistamatic, L.L.C. for free Get an email when a new federal OSHA severe-injury report for Vistamatic, L.L.C. is published. One employer, no account, unsubscribe in one click.
Establishment
VISTAMATIC, L.L.C.
Site address
11713 NW 39TH STREET
City
CORAL SPRINGS
State
FL
ZIP
33065
Mailing
11713 NW 39TH STREET, CORAL SPRINGS, FL 33065
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327211
Employees
30
Ownership type
Private (A)

6 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 8, 2019
Penalty
Initial $4,508 · Current $2,704 Reduced

Hazardous substances 2590

29 CFR 1910.106(d)(2)(i): Approved containers and/or portable tanks were not used for the storage of flammable liquids:    On or about 1/29/2019, at 11713 NW 39th St. Coral Springs, FL 33065 paint room, the xylene was stored in a 5 gallon plastic bucket, exposing the employees to a fire hazard.
Recent events (2)
  • · I (S) $2704
  • · Z (S) $4508

1910.106 E02 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(a): Flammable liquids were not kept in covered container(s) when not actually in use:  On or about 1/29/2019, at 11713 NW 39th St. Coral Springs, FL 33065 paint room, a plastic bucket was kept uncovered while containing Xylene, exposing employees to a fire hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.106 E06 II

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 8, 2019
Penalty
Initial $4,508 · Current $2,704 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers without the nozzle and container being electrically interconnected:    On or about, at 11713 NW 39th St. Coral Springs, FL 33065 paint room, the employer had a fifty five (55) gallon drum of Xylene that was not grounded; exposing employees to a fire hazard.
Recent events (2)
  • · I (S) $2704
  • · Z (S) $4508

1910.305 G01 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 8, 2019
Penalty
Initial $4,508 · Current $2,704 Reduced
29 CFR 1910.305(g)(1)(iv):   Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for the fixed wiring of a structure:    On or about 01/29/2019, at 11713 NW 39th St. Coral Springs, FL 33065 break room, the employer had used an extension cord to power the water dispenser, exposing employees to an electrical hazard.          -
Recent events (2)
  • · I (S) $2704
  • · Z (S) $4508

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  On or about 01/29/2019, at 11713 NW 39th St. Coral Springs, FL 33065 painting room, the employer did not provide employees, who voluntarily wore a Safety Works air purifying respirator, with a medical evaluation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
Feb 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  On or about 01/29/2019, at 11713 NW 39th St. Coral Springs, FL 33065 painting room, the employer did not provide a copy of the appendix D to those employees who voluntarily wore a Safety Works air purifying respirator while working at the facility.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343745873.