OSHA Inspection: COMPUNET CLINICAL LABORATORIES, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COMPUNET CLINICAL LABORATORIES, LLC in ONE WYOMING STREET, DAYTON, OH 45409 (NAICS 541380). OSHA activity number 343745899.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Compunet Clinical Laboratories, LLC — free Get an email when a new federal OSHA severe-injury report for Compunet Clinical Laboratories, LLC is published. One employer, no account, unsubscribe in one click.
Site address
ONE WYOMING STREET
City
DAYTON
State
OH
ZIP
45409
Mailing
2308 SANDRIDGE DR., DAYTON, OH 45439
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541380
Employees
185
Ownership type
A

2 citations on file for this inspection.

1910.1450 F01

Other-than-serious 1 instance 4 exposed
Issued
Mar 13, 2019
Penalty
Initial $6,440 · Current $3,220 Reduced
29 CFR 1910.1450(f)(1): The employer did not provide laboratory employees with information and training to ensure that they were apprised of the hazards of chemicals present in their work area:    The employer did not provide training on the hazards associated with flammable aerosols for employees using Decon Labs, Inc. Flash Freeze (a flammable aerosol spray containing 1,1-diflouroethane ) while operating cryostats in the Histology Lab.
Recent events (2)
  • — I (O) $3220
  • — Z (S) $6440

1910.1450 H01 II

Other-than-serious 1 instance 4 exposed
Issued
Mar 13, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1450(h)(1)(ii): The employer did not maintain the safety data sheets that were received with incoming shipments of hazardous chemicals and ensure that they were readily accessible to laboratory employees.    The employer did not ensure that an updated safety data sheet (SDS) was accessible for Decon Labs, Inc. Flash Freeze (a flammable aerosol spray containing 1,1-diflouroethane ).