PONCE INLET, FL ·
OSHA Inspection: BOLD CITY ROOFING & RESTORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOLD CITY ROOFING & RESTORATION in 4493 ATLANTIC AVENUE, PONCE INLET, FL 32127 (NAICS 238160). OSHA activity number 343746038.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOLD CITY ROOFING & RESTORATION
- Site address
- 4493 ATLANTIC AVENUE
- City
- PONCE INLET
- State
- FL
- ZIP
- 32127
- Mailing
- 21795 NE 125TH AVE, FORT MC COY, FL 32134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 18
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B13
- Issued
- May 10, 2019
- Penalty
- Initial $5,304 · Current $3,182 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On or about January 14, 2019, two employees of Bold City Roofing & Restoration, the sub contractor on site, under the control of Roberson Roofing, Inc, were working on the one story 5:12 pitch, detached garage of the residence without fall protection and are exposed to falls of approximately 10 feet to the ground below. b. On or about January 14, 2019, two employees of Bold City Roofing & Restoration, the sub contractor on site, under the control of Roberson Roofing, Inc, were working on the one story 5:12 pitch, main residence without fall protection and are exposed to falls of approximately 10 feet to the ground below.
Recent events (2)
- · I (S) $3182.4
- · Z (S) $5304
1926.1053 B01
- Issued
- May 10, 2019
- Penalty
- Initial $4,546 · Current $2,728 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. On or about January 14, 2019 employees had set an aluminum extension ladder against the garage roof line and did not extend the ladder side rails to extend at least 3 feet (.9 m) above the upper landing surface being accessed, exposing employees to fall hazards of 10 feet to the ground below.
Recent events (2)
- · I (S) $2727.6
- · Z (S) $4546
1926.1053 B05 I
- Issued
- May 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support). a. On or about January 14, 2019 employees did not set the aluminum extension ladder they were using to access the roof at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder exposing employees to fall hazards of 10 feet to the ground.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B08
- Issued
- May 10, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder. a. On or about January 14, 2019 employees had set up an aluminum extension ladder against the residence to gain access to the roof. The ladder was set at the corner of the driveway near a dumpster and was not secured to the structure to prevent accidental displacement by work activities or traffic, exposing employees to fall hazards of 10 feet to the ground below.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.20 B01
- Issued
- May 10, 2019
- Penalty
- Initial $425 · Current $255 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard: a. On or about January 14, 2019, at the worksite, a safety and health program had not been initiated and maintained which addressed the basic elements of this standard.
Recent events (2)
- · I (O) $255
- · Z (O) $425
More inspections in this industry (NAICS 238160)