Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BOLD CITY ROOFING & RESTORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOLD CITY ROOFING & RESTORATION in 4493 ATLANTIC AVENUE, PONCE INLET, FL 32127 (NAICS 238160). OSHA activity number 343746038.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bold City Roofing & Restoration for free Get an email when a new federal OSHA severe-injury report for Bold City Roofing & Restoration is published. One employer, no account, unsubscribe in one click.
Site address
4493 ATLANTIC AVENUE
City
PONCE INLET
State
FL
ZIP
32127
Mailing
21795 NE 125TH AVE, FORT MC COY, FL 32134
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
18
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 2 instances 4 exposed
Issued
May 10, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a. On or about January 14, 2019, two employees of Bold City Roofing & Restoration, the sub contractor on site, under the control of Roberson Roofing, Inc, were working on the one story 5:12 pitch, detached garage of the residence without fall protection and are exposed to falls of approximately 10 feet to the ground below.  b. On or about January 14, 2019, two employees of Bold City Roofing & Restoration, the sub contractor on site, under the control of Roberson Roofing, Inc, were working on the one story 5:12 pitch, main residence without fall protection and are exposed to falls of approximately 10 feet to the ground below.
Recent events (2)
  • · I (S) $3182.4
  • · Z (S) $5304

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2019
Penalty
Initial $4,546 · Current $2,728 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a. On or about January 14, 2019 employees had set an aluminum extension ladder against the garage roof line and did not extend the ladder side rails to extend at least 3 feet (.9 m) above the upper landing surface being accessed, exposing employees to fall hazards of 10 feet to the ground below.
Recent events (2)
  • · I (S) $2727.6
  • · Z (S) $4546

1926.1053 B05 I

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support).  a. On or about January 14, 2019 employees did not set the aluminum extension ladder they were using to access the roof at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder exposing employees to fall hazards of 10 feet to the ground.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.1053 B08

Serious Gravity 5 1 instance 4 exposed
Issued
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder.  a. On or about January 14, 2019 employees had set up an aluminum extension ladder against the residence to gain access to the roof. The ladder was set at the corner of the driveway near a dumpster and was not secured to the structure to prevent accidental displacement by work activities or traffic, exposing employees to fall hazards of 10 feet to the ground below.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1926.20 B01

Other-than-serious 1 instance 4 exposed
Issued
May 10, 2019
Penalty
Initial $425 · Current $255 Reduced
29 CFR 1926.20(b)(1): A safety and health program was not initiated and maintained to provide compliance with the general safety and health provisions of the standard:   a. On or about January 14, 2019, at the worksite, a safety and health program had not been initiated and maintained which addressed the basic elements of this standard.
Recent events (2)
  • · I (O) $255
  • · Z (O) $425

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343746038.