ANNISTON, AL ·
OSHA Inspection: GENERAL DYNAMICS ORDNANCE AND TACTICAL SYSTEMS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of GENERAL DYNAMICS ORDNANCE AND TACTICAL SYSTEMS in 1425 COMMERCE BOULEVARD, ANNISTON, AL 36207 (NAICS 332721). OSHA activity number 343747556.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENERAL DYNAMICS ORDNANCE AND TACTICAL SYSTEMS
- Site address
- 1425 COMMERCE BOULEVARD
- City
- ANNISTON
- State
- AL
- ZIP
- 36207
- Mailing
- 1425 COMMERCE BOULEVARD, ANNISTON, AL 36207
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332721
- Employees
- 250
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.146 F04
- Issued
- Jul 17, 2019
- Abate by
- Aug 12, 2019
- Penalty
- Initial $904 · Current $542 Reduced
General-duty citation text
29 CFR 1910.146(f)(4): The entry permit that documented compliance and authorized entry to a permit space did not identify the authorized entrants within the permit space by name or by such other means (for example, through the use of rosters or tracking): (a) On or about 1/23/2019 - Heat Treat Area at Abar Ipsen Metal Master Horizontal Vacuum Furnace, the entry permit did document the second entrant who entered the space to replace the hot zone elements after the contractor incident.
Recent events (2)
- · I (O) $542.4
- · Z (O) $904
1910.146 F05
- Issued
- Jul 17, 2019
- Abate by
- Aug 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(f)(5): The entry permit that documented compliance and authorized entry to a permit space did not identify the personnel, by name, currently serving as attendants: (a) On or about 1/23/2019 - Heat Treat Area at Abar Ipsen Metal Master Horizontal Vacuum Furnace, the entry permit did not document the second attendant who was assigned to perform attendant duties while the hot zone elements were replaced after the contractor incident.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.146 G01
- Issued
- Jul 17, 2019
- Abate by
- Aug 12, 2019
- Penalty
- Initial $904 · Current $542 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: (a) On or about 1/23/2019 - Heat Treat Area at Abar Ipsen Metal Master Horizontal Vacuum Furnace, the employer did not provide training to the employee who was assigned to be the attendant when the hot zone elements were replaced after the contractor incident.
Recent events (2)
- · I (O) $542.4
- · Z (O) $904
More inspections at General Dynamics Ordnance and Tactical Systems
View General Dynamics Ordnance and Tactical Systems's full OSHA safety record →
More inspections in this industry (NAICS 332721)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343747556.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.