Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BUREAU OF INDIAN AFFAIRS WAPATO IRRIGATION PROJECT

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of BUREAU OF INDIAN AFFAIRS WAPATO IRRIGATION PROJECT in 413 SOUTH CAMAS AVENUE, WAPATO, WA 98951 (NAICS 924110). OSHA activity number 343750188.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bureau of Indian Affairs Wapato Irrigation Project — free Get an email when a new federal OSHA severe-injury report for Bureau of Indian Affairs Wapato Irrigation Project is published. One employer, no account, unsubscribe in one click.
Site address
413 SOUTH CAMAS AVENUE
City
WAPATO
State
WA
ZIP
98951
Mailing
413 SOUTH CAMAS AVENUE, WAPATO, WA 98951
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924110
Employees
50
Ownership type
D

6 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  A)     Employees were found to be overexposed to noise in the various remote pump houses located throughout the Irrigation system.  One employee was exposed to a noise level of 93.2 dBA over an 8 hour period, another was exposed to 89.8 dBA.  The employer did not have a hearing conservation program in place.
Recent events (1)
  • — Z (S) $0

1910.95 G06

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :  A)     Employees working at remote pump houses throughout the irrigation district, were exposed to noise levels above the permissible exposure limit.  One employee was exposed to a noise level of 93.2 dBA over an 8 hour period, and another employee was exposed to a noise level of 89.8. The employer did not have audiograms for these employees within the last 12 months.
Recent events (1)
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  A)     In the welding portion of the maintenance building, oxygen, and acetylene bottles were stored out on the floor with nothing in place to prevent them from falling over, or being knocked over by employees, fork lifts or materials being fabricated on nearby welding tables.  Some of the bottles that were stored out on the floor did not have caps on.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:  A)     In the welding shop and area immediately outside the shop oxygen and acetylene bottles were stored  next to each other.
Recent events (1)
  • — Z (S) $0

1910.303 G02 I D

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by elevation of 2.44 m (8.0 ft) or more above the floor or other working surface:  A)    In the maintenance shop there were hanging light bulb fixtures above work benches that did not have any form of protection from damage.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  A)     In the maintenance shop, an opening in a fixture box was not covered or otherwise closed off.
Recent events (1)
  • — Z (S) $0

View Bureau of Indian Affairs Wapato Irrigation Project's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343750188.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.