COATESVILLE, PA —
OSHA Inspection: NATHAN TROTTER & CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATHAN TROTTER & CO., INC. in 241 W STEWART HUSTON DR, COATESVILLE, PA 19320 (NAICS 331491). OSHA activity number 343750675.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATHAN TROTTER & CO., INC.
- Site address
- 241 W STEWART HUSTON DR
- City
- COATESVILLE
- State
- PA
- ZIP
- 19320
- Mailing
- 241 W STEWART HUSTON DR, COATESVILLE, PA 19320
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331491
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 19, 2019
- Abate by
- Jul 31, 2019
- Penalty
- Initial $6,630 · Current $4,310 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Jobsite - Tin Slot Line, Water Tank, Auger - Employees were exposed to entanglement and amputation hazards while processing Shot with an auger that was not guarded. c) Jobsite - Double Stroke Solid Die Cold Header Machines, rotating discs feeding line of raw material - Employees processing Anodes were exposed to ingoing nip point hazards from the rotating discs that were unguarded. On or about 1/31/18.
Recent events (2)
- — I (S) $4309.5
- — Z (S) $6630
1910.303 G02 I
- Issued
- Jul 19, 2019
- Abate by
- Jul 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i). Jobsite: Electrical panel boxes behind shipping, 120/208 V Panel Box (second from overhead door) - The energized panel box was missing blanks for breakers #7, 9, 11, and 18 exposing employees to shock hazards. Observed on or about 1/31/18.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Jul 19, 2019
- Abate by
- Jul 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. Jobsite: Electrical panel boxes behind shipping, 120/208 V Panel Box (second from overhead door) - The energized panel box was missing a knockout on its right side exposing employees to shock hazards. Observed on or about 1/31/18.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Nathan Trotter & CO., INC.
View Nathan Trotter & CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331491)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343750675.