SOUTH YARMOUTH, MA ·
OSHA Inspection: NAIROMI ABAD
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of NAIROMI ABAD in YARMOUTH COMMONS 881 ROUTE 28, SOUTH YARMOUTH, MA 02664 (NAICS 238130). OSHA activity number 343751947.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NAIROMI ABAD
- Site address
- YARMOUTH COMMONS 881 ROUTE 28
- City
- SOUTH YARMOUTH
- State
- MA
- ZIP
- 02664
- Mailing
- 975 PLYMOUTH AVENUE APARTMENT 1, FALL RIVER, MA 02721
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 6
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.451 B03
- Issued
- Feb 6, 2019
- Abate by
- Mar 28, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling: Jobsite: Employees were installing vinyl siding from pump-jack scaffolding that was approximately sixteen (16) inches from the face of the work exposing them to falls.
Recent events (1)
- · Z (S) $2842
1926.451 C02
- Issued
- Feb 6, 2019
- Abate by
- Mar 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: Jobsite: Employees were installing vinyl siding from pump-jack scaffolding that was erected on sandy/dirt without mudsills or adequate firm foundation exposing them to falls and struck-by hazards.
Recent events (1)
- · Z (S) $0
1926.451 C03
- Issued
- Feb 6, 2019
- Abate by
- Mar 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: Jobsite: Employees were installing vinyl siding from pump-jack scaffolding that was erected on sandy/dirt out of plumb exposing them to falls and struck-by hazards.
Recent events (1)
- · Z (S) $0
1926.452 J02
- Issued
- Feb 6, 2019
- Abate by
- Mar 28, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. Jobsite: Employees were installing vinyl siding from pump-jack scaffolding that was over twenty-four (24) feet high and was not braced at the bottom and middle as required exposing employees to falls and struck-by hazards
Recent events (1)
- · Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343751947.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.