Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: COMMERCIAL MOVING SERVICES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of COMMERCIAL MOVING SERVICES, LLC in 800 MARSHALL PHELPS ROAD BUILDING 4, WINDSOR, CT 06095 (NAICS 493110). OSHA activity number 343752978.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Commercial Moving Services, LLC for free Get an email when a new federal OSHA severe-injury report for Commercial Moving Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
800 MARSHALL PHELPS ROAD BUILDING 4
City
WINDSOR
State
CT
ZIP
06095
Mailing
800 MARSHALL PHELPS ROAD BUILDING 3, UNIT A, WINDSOR, CT 06095
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
22
Ownership type
Private (A)

6 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 2 instances 10 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $3,031 · Current $1,516 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:   A.  On or about February 4, 2019, Deluxing Area:  Two side-hinged man doors underneath an illuminated EXIT sign at the front of the warehouse were locked during building occupancy.
Recent events (2)
  • · I (S) $1515.5
  • · Z (S) $3031

1910.37 A03

Serious Gravity 5 2 instances 10 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:  A.  On or about February 4, 2019, Deluxing Area:  Two side-hinged man doors underneath an illuminated EXIT sign at the front of the warehouse were blocked by the storage of a Deluxing cart and an office desk.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.36 H02

Serious Gravity 5 2 instances 10 exposed
Issued
Feb 11, 2019
Abate by
Mar 29, 2019
Penalty
Initial $3,031 · Current $1,516 Reduced
29 CFR 1910.36(h)(2): Outdoor exit route was not covered where snow or ice was likely to accumulate.  (Exception: Not required where employer can demonstrate that snow or ice will be removed before it can present a hazard)  A.  On or about February 4, 2019, In the following locations, snow and ice had been allowed to accumulate in an exit route:  1.  Receiving Door:  The emergency exit route outside the identified EXIT door had not been cleared of ice or snow from a previous snow storm.  The accumulation did not allow for the door to open fully.  The walkway to the lot had not been shoveled or sanded.  2.  Exit door at Bay #4:  The emergency exit door led to a snow- and ice-covered landing and four stairs that led to a parking lot that had not been cleared near the building.
Recent events (2)
  • · I (S) $1515.5
  • · Z (S) $3031

1910.178 A05

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 11, 2019
Abate by
May 10, 2019
Penalty
Initial $3,031 · Current $1,516 Reduced
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered:  A.  On or about February 4, 2019, Building 4 Warehouse:  The Tailift propane powered forklift was operated with 60" forks, which would have a 30" load center.  The load chart on the vehicle listed only data for a 24" load center.
Recent events (2)
  • · I (S) $1515.5
  • · Z (S) $3031

1910.178 A06

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 11, 2019
Abate by
May 10, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place:   A.  On or about February 4, 2019, Building 4 Warehouse:  The Caterpillar forklift, Model CC25, S/N 4EM05051, did not have a data plate with load rating chart.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 III

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 11, 2019
Abate by
Feb 15, 2019
Penalty
Initial $2,273 · Current $1,137 Reduced
29 CFR 1910.305(g)(1)(iii): Flexible cords and cables were used for purposes prohibited by subparagraphs (A) through (E) of this paragraph:   A.  On or about February 4, 2019, Bay 1:  An orange flexible extension cord was run from a wall outlet inside the building through the doorway to the outside of the building where it powered an engine heater on a diesel truck operated by the company.  The cord was subject to damage from being closed in the door, and employees exposed to electric shock hazards.
Recent events (2)
  • · I (S) $1136.5
  • · Z (S) $2273

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343752978.