TONAWANDA, NY —
OSHA Inspection: WASHINGTON MILLS TONAWANDA, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WASHINGTON MILLS TONAWANDA, INC. in 1000 EAST NIAGARA STREET, TONAWANDA, NY 14150 (NAICS 327910). OSHA activity number 343758611.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WASHINGTON MILLS TONAWANDA, INC.
- Site address
- 1000 EAST NIAGARA STREET
- City
- TONAWANDA
- State
- NY
- ZIP
- 14150
- Mailing
- 1000 EAST NIAGARA STREET, TONAWANDA, NY 14150
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327910
- Employees
- 33
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I C
- Issued
- Feb 14, 2019
- Abate by
- Mar 11, 2019
- Penalty
- Initial $8,051 · Current $6,038 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 02/04/2019 throughout the production areas; where the employer did not evaluate and certify each and every authorized employee performing lockout every year. Employees perform servicing and maintenance operations . ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $6038.25
- — Z (S) $8051
1910.147 C06 II
- Issued
- Feb 14, 2019
- Abate by
- Mar 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) On or about 02/04/2019 throughout the establishment; the annual review of the energy control procedures was not certified ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Washington Mills Tonawanda, INC.
View Washington Mills Tonawanda, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327910)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343758611.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.