Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BRII EAST INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BRII EAST INC. in 29 WYSOCKI PL, HACKENSACK, NJ 07601 (NAICS 493190). OSHA activity number 343758751.

Watch Brii East INC. — free Get an email when a new federal OSHA severe-injury report for Brii East INC. is published. One employer, no account, unsubscribe in one click.
Establishment
BRII EAST INC.
Site address
29 WYSOCKI PL
City
HACKENSACK
State
NJ
ZIP
07601
Mailing
29 WYSOCKI PL, HACKENSACK, NJ 07601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493190
Employees
16
Ownership type
A

6 citations on file for this inspection.

1910.23 E01 VII

Serious Gravity 5 1 instance 16 exposed
Issued
Penalty
Initial $3031.00 · Current $1970.00 Reduced
29 CFR 1910.23(e)(1)(vii): Mobile ladder stands and platforms did not have wheels or casters equipped with a system to impede horizontal movement when an employee is on the stand or platform:    (a): Warehouse - An industrial ladder was not equipped with a system to impede horizontal motion when an employee is standing on the ladder. The industrial ladder was used when the foot/weight activated step lock was not operational, on or about 02/11/2019.    There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $1970.15
  • — Z (S) $3031

1910.176 B

Serious Gravity 5 1 instance 16 exposed
Issued
Penalty
Initial $3789.00 · Current $2463.00 Reduced
29 CFR 1910.176(b): Storage of material created a hazard:  (a): Warehouse Racks #100 & #200 - Employees were exposed to struck-by and caught under hazards from the possible collapse of steel racks that were not bolted to the floor, on or about 02/04/2019.  There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $2462.85
  • — Z (S) $3789

1910.213 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5304.00 · Current $3448.00 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  (a): Facility - Workshop - Suitable guards were not provided on a table saw. An automatically adjusting guard was not provided on the table saw. The table saw was used without a point of operation guard, on or about February 18, 2019.  Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3447.6
  • — Z (S) $5304

1910.213 R04

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $5304.00 · Current $3448.00 Reduced
29 CFR 1910.213(r)(4): Suitable guard(s) were not provided to reduce to a minimum the hazard due to the point of operation of a compound miter saw:  (a): Facility - Workshop - Suitable guards were not provided on a compound miter saw. The self-adjusting guard was removed from the compound miter saw. A compound miter saw was used without a point of operation guard, on or about February 18, 2019.  There is no abatement certification or documentation required for this item.
Recent events (2)
  • — I (S) $3447.6
  • — Z (S) $5304

1910.305 G01 IV

Serious Gravity 1 3 instances 16 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $1477.00 Reduced
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)  (a): Facility - Upstairs -  Flexible wiring was used as a substitute for fixed wiring and was run through a hole in the window frame. A flexible extension cord was used in a permanent manner and was ran through the window frame into the warehouse to power electrical devices, on or about February 4, 2019.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).   (b): Facility - Downstairs Office -  Flexible wiring was used as a substitute for fixed wiring and was ran under a doorway. A flexible extension cord was used in a permanent manner and was ran under a doorway to power electrical devices, on or about February 15, 2019.  There is no abatement certification or documentation required for this item.   (c): Facility - Workshop -  Flexible wiring was used as a substitute for fixed wiring. A flexible extension cord was used in a permanent manner to power an air compressor, on or about February 19, 2019.  Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $1477.45
  • — Z (S) $2273

1910.178 L01 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck  (a): Warehouse - The employer did not ensure that each powered industrial truck operator had successfully completed the required training prior to operating a powered industrial truck. Operators did not complete practical training and operator evaluation.  Employees were operating powered industrial trucks without required training, on or about February 14, 2019.   There is no abatement certification or documentation required for this item.
Recent events (2)