EAST SYRACUSE, NY —
OSHA Inspection: ARTISTRY IN WOOD OF SYRACUSE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARTISTRY IN WOOD OF SYRACUSE, INC. in 6804 MANLIUS CENTER ROAD, EAST SYRACUSE, NY 13057 (NAICS 337127). OSHA activity number 343759668.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARTISTRY IN WOOD OF SYRACUSE, INC.
- Site address
- 6804 MANLIUS CENTER ROAD
- City
- EAST SYRACUSE
- State
- NY
- ZIP
- 13057
- Mailing
- 6804 MANLIUS CENTER ROAD, EAST SYRACUSE, NY 13057
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 22
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.157 G02
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $2,273 · Current $0 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) At the establishment, on or about 2/5/19: Annual training was not provided to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting in that the last training was done on 3/31/15. *ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b). Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2273
1910.212 A01
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $3,031 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Assembly, on or about 2/5/19: Rotating chuck on a Jet pedestal drill, Serial #000356, was not guarded. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2273
- — Z (S) $3031
1910.213 C01
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $5,304 · Current $5,304
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Custom Cabinet Area, on or about 2/5/19: A Powermatic table saw used for ripping filler pieces was not adequately guarded in that the guard did not automatically adjust above the table and above the material being cut. Abatement documentation must be submitted for this item.
Recent events (2)
- — I (S) $5304
- — Z (S) $5304
1910.213 D01
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: a) Custom Cabinet Area, on or about 2/5/19: A Paolini sliding table saw was not adequately guarded in that the guard did not completely enclose the saw above the table and above the material being cut. Abatement documentation must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C02
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Custom Cabinet Area, on or 2/5/19: A Powermatic table saw used for ripping filler pieces was not provided with a spreader. Abatement documentation but be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $5304
1910.213 C03
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) Custom Cabinet Area, on or about 2/5/19: A Powermatic table saw used for ripping filler pieces was not provided with non-kickback fingers or dogs to prevent material from being thrown back at operator. Abatement documentation must be submitted for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 H04
- Issued
- Mar 8, 2019
- Abate by
- Mar 20, 2019
- Penalty
- Initial $2,273 · Current $1,704 Reduced
General-duty citation text
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a) Millwork Area, on or about 2/5/19: A Delta radial arm saw did not return to the starting position when released by the operator. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1704
- — Z (S) $2273
1910.213 P04
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $3,031 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points: a) Millwork Area, on or about 2/5/19: Ingoing nip points on a General International edge sander were not guarded on the right side. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $2273
- — Z (S) $3031
1910.213 S06
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $3,031 · Current $0 Reduced
General-duty citation text
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards: a) Custom Cabinet Area, on or about 2/5/19: Poor housekeeping in that wood shavings and wood dust had accumulated on the floor around the Powermatic table saw. b) Assembly Area, on or about 2/5/19: Poor housekeeping in that wood shavings and wood dust had accumulated on the floor around the Makita cutoff saw and Jet drill press. c) Millwork Area, on or about 2/5/19: Poor housekeeping in that wood shavings and wood dust had accumulated on the floor around the General edger sander and the table saw and another area near the Powermatic bandsaw. Abatement certification must be submitted for these instances.
Recent events (2)
- — I (S) $0
- — Z (S) $3031
1910.304 G05
- Issued
- Mar 8, 2019
- Abate by
- Mar 20, 2019
- Penalty
- Initial $2,273 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) Finishing Dept., on or about 2/5/19: A Dayton pedestal fan was not grounded in that the ground pin was missing from the plug end. b) Custom Cabinet Area, on or about 2/5/19: A Porter Cable router, Serial #828044 was not grounded in that the ground pin was missing from the plug end. Abatement certification must be submitted for instance a.
Recent events (2)
- — I (O) $0
- — Z (S) $2273
1910.305 G01 IV A
- Issued
- Mar 8, 2019
- Abate by
- Mar 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Custom Cabinet Area, on or about 2/5/19: A two wire extension cord for powering battery chargers was strung along conduit above the workbench and being used as permanent wiring. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Mar 8, 2019
- Abate by
- Apr 12, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At the establishment, on or about 2/5/19: An evaluation of powered industrial truck operator's performance was not conducted at least once every three years in that the last evaluations conducted were March, 2008. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Artistry in Wood of Syracuse, INC.
View Artistry in Wood of Syracuse, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343759668.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.