OSHA Inspection: ELEMENT MATERIALS TECHNOLOGY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ELEMENT MATERIALS TECHNOLOGY in 80 KIMBERLY DRIVE, SOUTH WINDSOR, CT 06074 (NAICS 541380). OSHA activity number 343761441.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Element Materials Technology — free Get an email when a new federal OSHA severe-injury report for Element Materials Technology is published. One employer, no account, unsubscribe in one click.
Site address
80 KIMBERLY DRIVE
City
SOUTH WINDSOR
State
CT
ZIP
06074
Mailing
80 KIMBERLY DRIVE, SOUTH WINDSOR, CT 06074
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541380
Employees
91
Ownership type
A

5 citations on file for this inspection.

1910.303 G01 I B

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 19, 2019
Penalty
Initial $6,440 · Current $3,220 Reduced
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the working space did not permit at least a 90-degree opening of equipment doors or hinged panels:    ULTRASONIC DEPARTMENT:    On or about and at times prior to March 7, 2019, an emergency disconnect for the cranes on the northwest side of the department did not have ample working space to be able to open the door 90 degrees.
Recent events (2)
  • — I (S) $3220
  • — Z (S) $6440

1910.303 G01 I C

Serious Gravity 5 2 instances 10 exposed
Issued
Mar 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i)(C): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of work space was not clear and did not extend from the grade, floor, or platform to the height required by paragraph (g)(1)(vi) of 29 CFR 1910.303:  PRODUCTION AREA:  On or about February 6, 2019, electrical panels in the Shipping/Receiving and Ultrasonic Departments were blocked by stored materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 B03

Other-than-serious 1 instance 91 exposed
Issued
Mar 19, 2019
Penalty
Initial $1,611 · Current $806 Reduced
29 CFR 1904.29(b)(3): Each recordable injury or illness on the OSHA 300 Log and 301 Incident Report was not recorded within seven (7) calendar days of receiving information that a recordable injury or illness has occurred.    COMPANY-WIDE:    On or about and at times prior to February 6, 2019, the employer had not recorded on the OSHA 300 Log an injury that occurred on January 21, 2019 and resulted in restricted duty.  The injury would be appropriately captured  with a check in Column I (Restricted Duty/Transfer), 6 days restriction in Column L, and a check in Column M1.    Abatement Certification and Documentation is required.
Recent events (2)
  • — I (O) $806
  • — Z (O) $1611

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Mar 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  COMPANY-WIDE:  On or about and at times prior to February 6, 2019, the employer required employees to wear N-95 particulate respirators when making chemical additions to dip tanks.  The employer had not developed and implemented a written respiratory protection program.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 I

Other-than-serious 1 instance 20 exposed
Issued
Mar 19, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:  COMPANY-WIDE:  On or about and at times prior to February 6, 2019, the employees who were allowed to wear N-95 particulate respirators on a voluntary basis had not been provided with training in accordance with Appendix D of this standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Element Materials Technology's full OSHA safety record →