BINGHAMTON, NY ·
OSHA Inspection: ABOVE AND BEYOND CONTRACTING
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of ABOVE AND BEYOND CONTRACTING in 229 FRONT STREET, BINGHAMTON, NY 13901 (NAICS 238160). OSHA activity number 343763603.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABOVE AND BEYOND CONTRACTING
- Site address
- 229 FRONT STREET
- City
- BINGHAMTON
- State
- NY
- ZIP
- 13901
- Mailing
- 9 ALDRICH AVENUE, BINGHAMTON, NY 13903
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.451 C02
- Issued
- Mar 21, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates, mud sills or other adequate firm foundations: a) At the jobsite, on or about 2/5/19: Employees worked from a ladder jack scaffold that was built onto a 16:12 pitch shed roof where one of those ladder uprights was not braced from slipping along the slope of the roof.
Recent events (2)
- · I (S) $3978
- · Z (S) $3978
1926.502 D06 III
- Issued
- Mar 21, 2019
- Penalty
- Initial $3,978 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(iii): Snaphooks shall not be engaged to a Dee-ring to which another snaphook or other connector is attached. a) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached two lifelines to a single anchor D-ring. b) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached two lifelines to a single anchor D-ring.
Recent events (2)
- · I (S) $0
- · Z (S) $3978
1926.502 D15
- Issued
- Mar 21, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached. a) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached to anchors that were not installed according to the manufacturers instructions. b) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached to anchors that were not installed according to the manufacturers instructions. c) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached to anchors that were not installed according to the manufacturers instructions. d) At the jobsite, on or about 2/5/19: Employees worked on a 16:12 pitch roof, with a ground to eave height of 24 feet, where personal fall arrest systems that attached to anchors that were not installed according to the manufacturers instructions.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Mar 21, 2019
- Penalty
- Initial $2,842 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, on or about 2/5/19: Employees accessed a jack-plank on a 16:12 pitch roof from an extension ladder where that ladder did not extend at least 3 feet above the surface being accessed.
Recent events (2)
- · I (S) $0
- · Z (S) $2842
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343763603.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.