Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: KIMCO ENTERPRISE INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KIMCO ENTERPRISE INC in AGAPE CHRISTIAN SCHOOL SAN ANTONIO, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 343764304.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kimco Enterprise INC for free Get an email when a new federal OSHA severe-injury report for Kimco Enterprise INC is published. One employer, no account, unsubscribe in one click.
Site address
AGAPE CHRISTIAN SCHOOL SAN ANTONIO
City
SAIPAN
State
MP
ZIP
96950
Mailing
P. O. BOX 501190 SAIPAN MP, SAIPAN, MP 96950
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
Private (A)

3 citations on file for this inspection.

1926.300 B04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 27, 2019
Penalty
Initial $2,576 · Current $2,576
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded:  Middle of the building: A chop saw without the blade guard installed was used to cut metal tubing. Employees were exposed to amputation hazards.
Recent events (1)
  • · Z (S) $2576

1926.405 G02 IV

Serious Gravity 1 3 instances 2 exposed
Issued
Mar 27, 2019
Penalty
Initial $1,932 · Current $1,932
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws   In the gym south end: An electrical cord with the outer insulation pulled back from the plug was used to power a welder. Employees were exposed to electrical and fire hazards.
Recent events (1)
  • · Z (S) $1932

1926.502 D15

Other-than-serious 2 instances 2 exposed
Issued
Mar 27, 2019
Abate by
Apr 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached.  South end of the building: The scaffold railing of a free standing fabricated frame scaffolding set was used as a personal fall arrest anchor point. Employees were exposed to fall and struck by hazards
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343764304.