SAIPAN, MP ·
OSHA Inspection: KIMCO ENTERPRISE INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KIMCO ENTERPRISE INC in AGAPE CHRISTIAN SCHOOL SAN ANTONIO, SAIPAN, MP 96950 (NAICS 236220). OSHA activity number 343764304.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KIMCO ENTERPRISE INC
- Site address
- AGAPE CHRISTIAN SCHOOL SAN ANTONIO
- City
- SAIPAN
- State
- MP
- ZIP
- 96950
- Mailing
- P. O. BOX 501190 SAIPAN MP, SAIPAN, MP 96950
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 12
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.300 B04 II
- Issued
- Mar 27, 2019
- Penalty
- Initial $2,576 · Current $2,576
General-duty citation text
29 CFR 1926.300(b)(4)(ii): The point of operation of machine(s) whose operation exposed an employee to injury was not guarded: Middle of the building: A chop saw without the blade guard installed was used to cut metal tubing. Employees were exposed to amputation hazards.
Recent events (1)
- · Z (S) $2576
1926.405 G02 IV
- Issued
- Mar 27, 2019
- Penalty
- Initial $1,932 · Current $1,932
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws In the gym south end: An electrical cord with the outer insulation pulled back from the plug was used to power a welder. Employees were exposed to electrical and fire hazards.
Recent events (1)
- · Z (S) $1932
1926.502 D15
- Issued
- Mar 27, 2019
- Abate by
- Apr 4, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not capable of supporting at least 5,000 pounds per employee attached. South end of the building: The scaffold railing of a free standing fabricated frame scaffolding set was used as a personal fall arrest anchor point. Employees were exposed to fall and struck by hazards
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 236220)
More inspections in MP
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343764304.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.