Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: THERM-O-LINK

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERM-O-LINK in 10513 FREEDOM SREET, GARRETTSVILLE, OH 44231 (NAICS 335999). OSHA activity number 343770988.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Therm-O-Link for free Get an email when a new federal OSHA severe-injury report for Therm-O-Link is published. One employer, no account, unsubscribe in one click.
Establishment
THERM-O-LINK
Site address
10513 FREEDOM SREET
City
GARRETTSVILLE
State
OH
ZIP
44231
Mailing
10513 FREEDOM SREET, GARRETTSVILLE, OH 44231
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335999
Employees
183
Ownership type
Private (A)

2 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 2 exposed
Issued
May 30, 2019
Penalty
Initial $5,115 · Current $3,581 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained, so far as possible, in a dry condition.  Drainage was not maintained where wet process(es) were in use:  On or about February 7, 2019, the walking working surfaces around the Hendrix number 12 wire machine were saturated with coolant fluid causing the floor to be wet and slippery.
Recent events (2)
  • · I (S) $3580.5
  • · Z (S) $5115

1910.212 A01

Serious Gravity 5 3 instances 4 exposed
Issued
May 30, 2019
Abate by
Jun 19, 2019
Penalty
Initial $8,525 · Current $5,968 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about February 7, 2019, the following machines were not properly safeguarded.    1. DELETED in INFORMAL see signed ISA    2. The Redaelli #2 buncher machine Strander/Cabler/Twinner cabinet had an access door interlock assembly that was not attached to ensure the machine shut down when the access door is opened.    3. The Redaelli #3 buncher machine Strander/Cabler/Twinner cabinet access door interlock assembly was not in alignment with the pad eye opening to ensure the machine shut down when the access door is opened.
Recent events (2)
  • · I (S) $5967.5
  • · Z (S) $8525

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343770988.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.