OSHA Inspection: DUTCHLAND PLASTICS LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DUTCHLAND PLASTICS LLC in 54 ENTERPRISE CT., OOSTBURG, WI 53070 (NAICS 326199). OSHA activity number 343771580.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dutchland Plastics LLC — free Get an email when a new federal OSHA severe-injury report for Dutchland Plastics LLC is published. One employer, no account, unsubscribe in one click.
Site address
54 ENTERPRISE CT.
City
OOSTBURG
State
WI
ZIP
53070
Mailing
54 ENTERPRISE COURT, OOSTBURG, WI 53070
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
305
Ownership type
A

11 citations on file for this inspection.

1910.22 D02

Serious Gravity 5 3 instances 20 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $10,627 · Current $5,314 Reduced
29 CFR 1910.22(d)(2): The employer did not ensure hazardous conditions on walking-working surfaces were corrected or repaired before an employee used the walking-working surface again.  When the correction or repair cannot be made immediately, the hazard was not guarded to prevent employees from using the walking-working surface until the hazard is corrected or repaired:    a)    On or about 2/11/2019, Employer had slippery floors in the Foaming area that employees were exposed to.    b)    On or about 2/11/2019, there was standing water in the aisle to employee entrance/exit #11, in front of an electrical cabinet.    c)    On or about 2/11/2019, there was a drain cover that was missing for a floor drain on the air compressor mezzanine.
Recent events (2)
  • — I (S) $5313.5
  • — Z (S) $10627

1910.25 B03

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.25(b)(3): The employer did not ensure that stairs have uniform riser heights between landings:  a)    On or about 2/11/2019, the employer had stairs by the mixer platform that did not have uniform riser heights for all of the steps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.29 B02 I

Serious Gravity 5 1 instance 3 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2)(i): 29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface:  a)    On or about 2/11/2019, There was not a mid-rail on the railing system for the top of oven #17 facing the storage mezzanine.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 II

Serious Gravity 5 1 instance 8 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $8,856 · Current $4,428 Reduced
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:    a)    On or about 2/8/2019, Employer had not completed their annual periodic inspections with any of their maintenance employees which are LOTO authorized.
Recent events (2)
  • — I (S) $4428
  • — Z (S) $8856

1910.178 N11

Serious Gravity 10 5 instances 5 exposed
Issued
May 10, 2019
Abate by
May 20, 2019
Penalty
Initial $13,260 · Current $4,428 Reduced
29 CFR 1910.178(n)(11): Dockboard(s) or bridgeplate(s) were not properly secured before they were driven over:    a)    On or about 2/8/2019, Employees were using Dock #1 with amber caution light lit on the POWERAMP control panels and duct tape over the Engage/Release buttons.    b)    On or about 2/8/2019, Employees were using Dock #3 with the amber caution light lit on the POWERAMP control panels and duct tape over the Engage/Release buttons.    c)    On or about 2/8/2019, Employees were using Dock #4 with the amber caution light lit on the POWERAMP control panels and duct tape over the Engage/Release buttons.    d)    On or about 2/8/2019, Employees were using the two docks by exit Door #11 with amber caution lights lit on the POWERAMP control panels and duct tape over the Engage/Release buttons.
Recent events (2)
  • — I (S) $4428
  • — Z (S) $13260

1910.212 A01

Serious Gravity 10 3 instances 9 exposed
Issued
May 10, 2019
Abate by
Aug 17, 2019
Penalty
Initial $13,260 · Current $6,630 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)    On or about 2/8/2019, A struck by hazard existed by #7 oven where a 7' gap in the guarding existed in the chiller opening where the machine turns between the platform and the work ahead area.    b)    On or about 2/8/2019, A struck by hazard existed where the rotator arm access was not protected due to barrier guard chains being damaged and broken for #10 Oven area.    c)    On or about 2/8/2019, A struck by hazard existed where employees were cleaning in the lower level while the equipment was still spinning for oven #14 without barrier guard protection. There was also exposure at the operators level where the guard wires were in need of repair and not utilized.
Recent events (2)
  • — I (S) $6630
  • — Z (S) $13260

1910.212 A02

Serious Gravity 5 1 instance 11 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(2): General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself.  a)    On or about 2/8/2019, A hazard existed on Oven #7 because of a damaged expanded metal guard which created a laceration hazard for employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 IV F

Serious Gravity 5 1 instance 8 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(iv)(f): The point of operation of power saws whose operation exposed an employee to injury were not guarded:  a)    On or about 2/8/2019, The company had a laceration hazard with the JET horizontal saw not having the unused portion of the saw blade guarded in the maintenance shop.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 8 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  a)    On or about 2/8/2019, Struck by hazard from missing non kickback fingers or dogs on 10" DELTA Contractors Saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 2 instances 6 exposed
Issued
May 10, 2019
Abate by
May 20, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  a)    On or about 2/8/2019, Air wand hanging on the side of the Sand blast booth for cleaning did not have a pressure relieving tip on it.  b)    On or about 2/8/2019, Air wands at Oven #14 platform did not have a pressure relieving tip on it.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 B02

Other-than-serious 2 instances 6 exposed
Issued
May 10, 2019
Abate by
Jun 17, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)    On or about 2/11/2019, Relocatable Power Taps were being used without being plugged directly into permanently wired outlets as required. (Oven platform for #13 and on air compressor mezzanine.)
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dutchland Plastics LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343771580.