Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: RIVERWOODS CABINETRY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RIVERWOODS CABINETRY, LLC in 139 BARKEY HOFFMAN ROAD, HARRISVILLE, PA 16038 (NAICS 321999). OSHA activity number 343772588.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Riverwoods Cabinetry, LLC for free Get an email when a new federal OSHA severe-injury report for Riverwoods Cabinetry, LLC is published. One employer, no account, unsubscribe in one click.
Site address
139 BARKEY HOFFMAN ROAD
City
HARRISVILLE
State
PA
ZIP
16038
Mailing
139 BARKEY HOFFMAN ROAD, HARRISVILLE, PA 16038
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
6
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 2 instances 6 exposed
Issued
Jun 11, 2019
Abate by
Dec 9, 2019
Penalty
Initial $2,842 · Current $1,500 Reduced
OSH ACT of 1970 Section (5)(a)(1): OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:      A.)  Riverwoods Cabinetry, LLC; outside dust collector - On or about 2/8/19, and at times prior thereto, employees were potentially exposed to fire, burn, and deflagration hazards from a dust collector that was not equipped with devices and systems to prevent the propagation of deflagration and associated flame fronts from the dust collector through the associated dust collection system duct work and back into the building.  The dust collector was not equipped with approved devices to prevent the propagation of deflagration and associated flame fronts throughout the dust collection system.  The dust collector collected wood dust.
Recent events (3)
  • · P (S) $1500
  • · I (S) $1500
  • · Z (S) $2842

1910.147 C07 I B

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $1,705 · Current $1,500 Reduced
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:    A.)  Riverwoods Cabinetry, LLC; production area - On or about 2/8/19, and at times prior thereto, employees had not received affected lockout/tagout training. Employees work near and around equipment that is locked out for repairs and preventative maintenance.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $1705

1910.178 L01 I

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $2,273 · Current $1,500 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):      A.)  Riverwood Cabinetry, LLC. - On or about 2/8/19, and at times prior thereto, employees were operating the forklift without being trained and evaluted.  Employees would use the trucks to load and unload trucks.  Employees operated forklifts that included, but were not limited to, the Clark forklift.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2273

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $3,410 · Current $1,500 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:      A.)  Riverwoods Cabinetry, LLC; production area - On or about 2/8/19, and at times prior thereto, the Powermatic table saw did not have a guard over the saw blade.  The saw was used to cut and rip wood.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $3410

1910.213 C02

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator:   A.)  Riverwoods Cabinetry, LLC; production area - On or about 2/8/19, and at times prior thereto, the Powermatic table saw did not have a spreader installed to prevent wood being kicked back.  The saw was used to cut and rip wood.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.213 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator:  A.)  Riverwoods Cabinetry, LLC; production area - On or about 2/8/19, and at times prior thereto, the Powermatic table saw did not have kickbacks installed.  The saw was used to cut and rip wood.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 E02

Other-than-serious 1 instance 6 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:   A.) Riverwoods Cabinetry, LLC; throughout facility - On or about 2/8/19, and at times prior thereto, portable fire extinguishers had not received monthly visual inspections.  The last inspection on the fire extinguisher tags listed 2015 as the inspection date and the monthly inspections for 2015 were not noted on the tags.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E03

Other-than-serious 1 instance 6 exposed
Issued
Jun 11, 2019
Abate by
Jul 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:   A.) Riverwoods Cabinetry, LLC; throughout facility - On or about 2/8/19, and at times prior thereto, portable fire extinguishers had not received an annual inspection.  The last inspection on the fire extinguisher tags listed 2015 as the inspection date.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Riverwoods Cabinetry, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343772588.