On , OSHA opened a complaint safety inspection of D & A GENERAL CONSTRUCTION LLC in 230-250 AVENUE E, BAYONNE, NJ 07002 (NAICS 238350). OSHA activity number 343776019.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & A GENERAL CONSTRUCTION LLC
- Site address
- 230-250 AVENUE E
- City
- BAYONNE
- State
- NJ
- ZIP
- 07002
- Mailing
- 36 LENTZ AVE APT 1F, NEWARK, NJ 07105
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.25 A
- Issued
- Apr 11, 2019
- Abate by
- May 1, 2019
- Penalty
- Initial $2,842 · Current $1,648 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures. a) Ground floor- Debris was not kept cleared from the work area; on or about 2/11/19.
Recent events (2)
- — I (S) $1648.36
- — Z (S) $2842
1926.451 E01
- Issued
- Apr 11, 2019
- Abate by
- May 1, 2019
- Penalty
- Initial $3,978 · Current $2,307 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) 1st floor level- Employees were climbing the rails of a scissor lift as a means of access to a scaffold; on or about 2/11/19.
Recent events (2)
- — I (S) $2307.24
- — Z (S) $3978
1926.451 G01 VII
- Issued
- Apr 11, 2019
- Abate by
- May 1, 2019
- Penalty
- Initial $3,978 · Current $2,307 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) 1st floor level- Employee was exposed to a fall of up to approximately 10ft while working on a single plank scaffold without the use of a personal fall arrest system or guardrail system; on or about 2/11/19.
Recent events (2)
- — I (S) $2307.24
- — Z (S) $3978
1926.501 B01
- Issued
- Apr 11, 2019
- Penalty
- Initial $3,978 · Current $2,307 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) 1st floor level- Employees were exposed to a fall of approximately 10ft fall while working on a canopy without a fall protection system; on or about 2/11/19.
Recent events (2)
- — I (S) $2307.24
- — Z (S) $3978
1926.1051 A
- Issued
- Apr 11, 2019
- Abate by
- May 1, 2019
- Penalty
- Initial $2,273 · Current $1,430 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Ground floor- Employees were not provided with a ladder for access where there was a break in elevation of more than 19 inches; on or about 2/11/19.
Recent events (2)
- — I (S) $1429.92
- — Z (S) $2273
More inspections at D & a General Construction LLC
View D & a General Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238350)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343776019.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.