DALLAS, TX ·
OSHA Inspection: 3 L DESIGNS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 3 L DESIGNS, INC. in 8821 DIRECTORS ROW, DALLAS, TX 75247 (NAICS 337110). OSHA activity number 343778742.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 3 L DESIGNS, INC.
- Site address
- 8821 DIRECTORS ROW
- City
- DALLAS
- State
- TX
- ZIP
- 75247
- Mailing
- 8821 DIRECTORS ROW, DALLAS, TX 75247
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 8
- Ownership type
- Private (A)
Citations
11 citations on file for this inspection.
1910.133 A02
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $3,789 · Current $2,250 Reduced
General-duty citation text
29 CFR 1910.133(a)(2): The employer shall ensure that each affected employee uses eye protection that provides side protection when there is a hazard from flying objects. Detachable side protectors (e.g. clip-on or slide-on side shields) meeting the pertinent requirements of this section are acceptable. a) Employees operating hand fed rip saws are exposed to eye injuries when working without side shields on their prescription glasses.
Recent events (2)
- · I (S) $2250
- · Z (S) $3789
1910.141 D02 II
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $2,273 · Current $0 Reduced
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: a) On or before February 12, 2019 at the site, employees were exposed to unsanitary conditions when only cold water was available for employees to wash their hands.
Recent events (2)
- · I (O) $0
- · Z (S) $2273
1910.212 B
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $3,031 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: (a) On or before February 12, 2019 employees at the site were exposed to struck-by hazards when a Delta 16 1/2 in drill press was not secured to the floor.
Recent events (2)
- · I (S) $1800
- · Z (S) $3031
1910.213 C01
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,304 · Current $3,700 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: Employees at the site were exposed to amputation hazards while operating the following unguarded circular handfed ripsaws: 1) Delta X 5 Uninsaw 2) Powermatic 111 #1 3) Powermatic 111 #2 4) Sawstop PCS 175
Recent events (2)
- · I (S) $3700
- · Z (S) $5304
1910.213 C02
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: a) Employees at the site were exposed to amputation hazards while operating the following circular handfed ripsaws without a spreader bar installed: 1) Delta X 5 Uninsaw 2) Powermatic 111 #1 3) Powermatic 111 #2 4) Sawstop PCS 175
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.213 C03
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: a) Employees at the site were exposed to amputation hazards while operating the following circular handfed ripsaws which did not have non kickback fingers installed. 1) Delta X 5 Uninsaw 2) Powermatic 111 #1 3) Powermatic 111 #2 4) Sawstop PCS 175
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,304 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) On or before February 12, 2019 employees at the site in the area of the Sawstop saw were exposed to electrical shock hazards where a permanent mount receptacle box and receptacle was connected to a flexible cable.
Recent events (2)
- · I (S) $3000
- · Z (S) $5304
1910.303 C03 I
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $3,789 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. a) On or before February 12, 2019 at the site above the Sawstop table saw, employees were exposed to electrical shock hazards where conductors were not spliced with devices identified for the use, or by brazing, welding or soldering.
Recent events (2)
- · I (S) $0
- · Z (S) $3789
1910.305 B01 II
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) On or before February 12, 2019 on the north wall at the site, employees were exposed to electrical shock hazards where a 220 volt breaker box contained six unused openings that had not been closed.
Recent events (2)
- · I (S) $0
- · Z (S) $5304
1910.305 G01 IV D
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,304 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces: (a) Employees at the site were exposed to electrical shock hazards when a flexible cord was attached to the rafters of the structure.
Recent events (2)
- · I (S) $0
- · Z (S) $5304
1910.305 B02 I
- Issued
- Apr 3, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,304 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or before February 12, 2019 near the chop saw at the site employees were exposed to electrical shock and or burns when a 4-receptacle box did not have a face plate.
Recent events (2)
- · I (S) $3000
- · Z (S) $5304
More inspections at 3 L Designs, INC.
View 3 L Designs, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343778742.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.