LAWRENCEVILLE, GA —
OSHA Inspection: OPTIMA STANTRON CORP. DIV OF ELMA ELECTRONIC INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of OPTIMA STANTRON CORP. DIV OF ELMA ELECTRONIC INC. in 1775 MACLEOD DR, LAWRENCEVILLE, GA 30043 (NAICS 334515). OSHA activity number 343787040.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OPTIMA STANTRON CORP. DIV OF ELMA ELECTRONIC INC.
- Site address
- 1775 MACLEOD DR
- City
- LAWRENCEVILLE
- State
- GA
- ZIP
- 30043
- Mailing
- 1775 MCLEOD DRIVE, LAWRENCEVILLE, GA 30043
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334515
- Employees
- 65
- Ownership type
- A
Citations
15 citations on file for this inspection.
1910.102 A
- Issued
- Aug 6, 2019
- Penalty
- Initial $9,472 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.102(a): In-plant transfer, handling, storage, and/or use of acetylene in cylinders did not comply with the provisions of CGA Pamphlet G-1-2009 ("Acetylene"): On or about 2/14/2019, workers walking in and around the storage area were exposed to smoke inhalation and thermal burn hazards where the unsecured acetylene cylinder was stored without a valve cap.
Recent events (2)
- — I (S) $5700
- — Z (S) $9472
1910.253 B04 III
- Issued
- Aug 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: On or about 2/14/2019, behind the paint booth, workers walking by or receiving materials from the area where unsecured oxygen and acetylene cylinder were stored within 1-foot of each other were exposed to smoke inhalation and thermal burn hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C04
- Issued
- Aug 6, 2019
- Abate by
- Sep 30, 2019
- Penalty
- Initial $9,472 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: On or about 2/14/2019, the employer's written permit required confined space program did not identify the dust collector as a permit required confined space. Employees entering the dust collector during filter change operations were exposed to fall hazards of approximately 4-feet. Employees worked inside the dust collector from 2-inch metal beams with 12-inches between each beam.
Recent events (2)
- — I (S) $5700
- — Z (S) $9472
1910.147 C01
- Issued
- Aug 6, 2019
- Abate by
- Sep 30, 2019
- Penalty
- Initial $13,260 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about 2/19/2019, an employee performed servicing and maintenance activities on machines and equipment such as, but not limited to the Cincinnati press brake, S/N 45136. The employee performing maintenance was not provided lockout or tagout devices to isolate energy sources, inspections on lockout procedures were not performed, nor was training provided to employees on the energy control measures.
Recent events (2)
- — I (S) $8000
- — Z (S) $13260
1910.157 E02
- Issued
- Aug 6, 2019
- Penalty
- Initial $9,472 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about 2/14/2019, monthly inspections of portable fire extinguishers were not performed since February 2018. Employees expected to fight incipient level fires were exposed to smoke inhalation and thermal burn hazards.
Recent events (2)
- — I (S) $5700
- — Z (S) $9472
1910.157 G01
- Issued
- Aug 6, 2019
- Abate by
- Sep 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting: On or about 2/14/2019, throughout the facility, employees were exposed to fire and explosion hazards where combustible dust was present in that they were expected to fight incipient level fires where the employer failed to provide training on the use of portable fire extinguishers.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Aug 6, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $9,472 · Current $5,700 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: On or about 2/14/2019, employees utilize PIT to transport product throughout the facility. Powered industrial truck operators were not evaluated since 2013 to ensure safe operation.
Recent events (2)
- — I (S) $5700
- — Z (S) $9472
1910.178 N06
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(n)(6): Industrial truck drivers were not required to look in the direction of, and keep a clear view of the path of travel: a. On or about 2/14/2019, two employees were observed not looking in the direction of travel while operating a forklift to transport materials in the facility. Employees were exposed to struck-by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 6, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $13,260 · Current $8,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation: a. On or about 2/14/2019 in the cabinet assembly area, tip tables 1 through 5 were not guarded to prevent caught-in and crushing hazards during operations. b. Workers were exposed to amputation hazards where there was no guarding installed at the unused portions of the Amada horizontal band saw. c. at the Amada press brake, S/N HD 1003 NT, two workers were observed performing braking operations where only one operator utilized the foot pedal to actuate the brake. The second foot pedal was not in use as the machine was set up for operation by one person. Employees were exposed to amputation hazards.
Recent events (2)
- — I (S) $8000
- — Z (S) $13260
1910.242 B
- Issued
- Aug 6, 2019
- Penalty
- Initial $11,366 · Current $6,800 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 P.S.I.: On or about 2/14/2019 throughout the facility, workers observed performing daily cleaning tasks of materials including but not limited to powder coating dust and metal chips and shavings from work areas and their person with compressed air. Employees were exposed to embolism and struck by hazards where the compressed air was measured at above 100 P.S.I.
Recent events (2)
- — I (S) $6800
- — Z (S) $11366
1910.303 B01 IV
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $7,577 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electric equipment was not free from recognized hazards that were likely to cause serious physical harm to employees, such as damaged electrical insulation: a. On or about 2/14/2019 at the Cincinnati press break S/N 45136 workers plugging and unplugging a 110V fluorescent light were exposed to electrical shock and burn hazards where the plug was repaired with electricians tape to create the housing for the plug.
Recent events (2)
- — I (S) $4500
- — Z (S) $7577
1910.303 B02
- Issued
- Aug 6, 2019
- Abate by
- Aug 23, 2019
- Penalty
- Initial $7,577 · Current $4,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about 2/14/2019, employees throughout the facility were exposed to electric shock hazards at locations including but not limited to: a) the weld shop, equipment such as but not limited to the lift tables and hand tools were receiving power from flexible cords plugged into metal electrical junction boxes with prepunched knockouts used as extension cords and not mounted to a rigid surface. b) hydraulic press areas, equipment such as but not limited to the radio and hand tools was receiving power from flexible cords plugged into metal electrical junction boxes with prepunched knockouts used as extension cords and not mounted to a rigid surface. c) Buffalo pedestal drill press, was receiving power from flexible cords plugged into metal electrical junction boxes with prepunched knockouts used as extension cords and not mounted to a rigid surface.
Recent events (2)
- — I (S) $4500
- — Z (S) $7577
1910.305 B01 II
- Issued
- Aug 6, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $11,366 · Current $6,800 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about 2/14/2019: a. in the cabinet assembly area, table 1, workers were exposed to electrical shock and burn hazards where the tipper table, 480V, Square D, electrical knife switch was missing a 1-inch knock out. b. in the cabinet assembly area, table 2, workers were exposed to electrical shock and burn hazards where the tipper table, 480V, Square D, electrical knife switch was missing a 1-inch knock out. c. in the cabinet assembly area, table 4, workers were exposed to electrical shock and burn hazards where the tipper table, 480V, Push On, electrical knife switch was missing a 1 1/2-inch knock out. d. in the cabinet assembly area, table 5, workers were exposed to electrical shock and burn hazards where the tipper table, 480V, GE, electrical knife switch was missing a 1-inch knock out. e. in the milling machine area, workers walking by or working in the vicinity of the exhaust fan No. 3, 480V, Square D, electrical knife switch was missing a 3/4-inch knock out were exposed to electrical shock and burn hazards if contact were made. f. at the Amada Horizontal band saw, workers were exposed to electrical shock and burn hazards where the 220V, knife switch was missing a 3/4-inch knock out. g. at the 10-foot Accushear, workers were exposed to electrical shock and burn hazards where the LOTO handle was missing, creating an unused opening that had exposed 460V electrical components. h. On or about 2/14/2019 at the 10-foot Accushear, workers were exposed to electrical shock and burn hazards where there was an unused opening exposing the 460V electrical components.
Recent events (2)
- — I (S) $6800
- — Z (S) $11366
1910.305 G02 III
- Issued
- Aug 6, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $5,683 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about 2/14/2019 throughout the facility, workers plugging and unplugging electrical equipment were exposed to electrical shock and burn hazards where there strain relief was not provided on equipment including but not limited to: a. Baldor bench grinder S/N W883 b. Cincinnati press break S/N 45136, industrial power strip powering fluorescent light
Recent events (2)
- — I (S) $3400
- — Z (S) $5683
1910.178 Q07
- Issued
- Aug 6, 2019
- Abate by
- Aug 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: On or about 2/14/2019, throughout the facility powered industrial trucks were not inspected at the beginning of shift or before use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Optima Stantron Corp. DIV of Elma Electronic INC.
View Optima Stantron Corp. DIV of Elma Electronic INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334515)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343787040.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.