EAST MOLINE, IL —
OSHA Inspection: LIFT SYSTEMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LIFT SYSTEMS, INC. in 1505 7TH STREET, EAST MOLINE, IL 61244 (NAICS 333923). OSHA activity number 343788964.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LIFT SYSTEMS, INC.
- Site address
- 1505 7TH STREET
- City
- EAST MOLINE
- State
- IL
- ZIP
- 61244
- Mailing
- 1505 7TH STREET, EAST MOLINE, IL 61244
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333923
- Employees
- 23
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 E06 II
- Issued
- Apr 17, 2019
- Penalty
- Initial $5,834 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C) were dispensed into containers without electrically interconnecting the nozzle and the container: On or about February 15, 2019, employees were exposed to fire and smoke inhalation hazards when they dispensed PPG and Sherwin Williams coatings mixed with Vietek Wash Thinner without electrically interconnecting a funnel used to catch the spent solvent wash from the paint guns into a 55-gallon metal drum.
Recent events (2)
- — I (O) $2500
- — Z (S) $5834
1910.151 C
- Issued
- Apr 17, 2019
- Penalty
- Initial $5,834 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: On or about February 15, 2019, employees were exposed to eye injury (corrosive coatings and battery acid) and the employer provided a Honeywell Porta Stream emergency eyewash (Model 2300; S/N 540232) that contained stored water which was unsuitable for use because it was not changed as required by the manufacturer.
Recent events (2)
- — I (O) $2500
- — Z (S) $5834
1910.178 P01
- Issued
- Apr 17, 2019
- Penalty
- Initial $5,834 · Current $3,792 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) with defect(s) or in any way unsafe had not been withdrawn from service until restored to safe operating condition(s): On or about February 18, 2019, employees operated a Yale Model ERC060HBN365V083 (Serial Number N448267) forklift and the employer failed to ensure all powered industrial vehicles were removed from service when found to be in need of repair due to the following: a) brake failure; and b) exposed inner wiring at the battery terminal.
Recent events (2)
- — I (S) $3792.1
- — Z (S) $5834
1910.179 J02 I
- Issued
- Apr 17, 2019
- Abate by
- Jul 24, 2019
- Penalty
- Initial $4,376 · Current $2,844 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(i): Frequent inspections, including the daily inspection all functional operating mechanisms for maladjustment that interfered with proper operation between regular inspections, were not performed. In February 2019, the employer did not complete daily inspections for brake function and employees in the Fab Weld Department were exposed to struck-by hazards when they used the 20-ton crane (Make MMM; Model 2; S/N 56-36355BM) and the bridge brake did not work properly.
Recent events (2)
- — I (S) $2844.4
- — Z (S) $4376
1910.179 L03 I
- Issued
- Apr 17, 2019
- Abate by
- Jul 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(l)(3)(i): Unsafe conditions disclosed by the inspection requirements of 29 CFR 1910.179(j) were not corrected as required by designated personnel: In February 2019, employees in the Fab Weld Department were exposed to struck-by hazards when they used the 20-ton crane (Make MMM; Model 2; S/N 56-36355BM) and the bridge brake did not operate properly (as noted in the Quad City Testing Laboratory inspection report, January 18, 2019) and the employer did not correct the unsafe condition.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01 I
- Issued
- Apr 17, 2019
- Abate by
- May 2, 2019
- Penalty
- Initial $5,834 · Current $3,792 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate material safety data sheet: On or about February 19, 2019, the employer did not maintain a hazardous chemical inventory list at the site and employees applied coatings, welded metal, and adjusted forklift battery acid concentration and were not provided with a hazardous chemical inventory list.
Recent events (2)
- — I (S) $3792.1
- — Z (S) $5834
1910.1200 H01
- Issued
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about February 19, 2019, the employer did not provide employees information and training on the hazardous chemicals in their work area, including the hazard labels and pictograms, and the employees that painted metal parts were exposed to the following hazardous chemicals: a) PPG Amercoat 450H Neutral Tint Resin; and b) Vietek Thinner.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 D02
- Issued
- Apr 17, 2019
- Abate by
- May 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: On or about February 15, 2019, the employer did not evaluate, develop, and document a personal protective equipment hazard assessment for the welding and painting tasks nor did they complete a written certification that included the name of the person who certified that the evaluation had been performed and the date that the hazard assessment was completed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Lift Systems, INC.
View Lift Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333923)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343788964.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.