Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: REX HARPER DBA REH PROPERTY MAINTENANCE

Unprogrammed Related inspection · Health discipline

On , OSHA opened an unprogrammed Related health inspection of REX HARPER DBA REH PROPERTY MAINTENANCE in SUPERIOR STEEL DOOR & TRIM CO, INC. 55 JONES & GIFFORD AVE., JAMESTOWN, NY 14701 (NAICS 238990). OSHA activity number 343793915.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch REX Harper DBA REH Property Maintenance for free Get an email when a new federal OSHA severe-injury report for REX Harper DBA REH Property Maintenance is published. One employer, no account, unsubscribe in one click.
Site address
SUPERIOR STEEL DOOR & TRIM CO, INC. 55 JONES & GIFFORD AVE.
City
JAMESTOWN
State
NY
ZIP
14701
Mailing
41 WESTCOTT STREET UPPER, JAMESTOWN, NY 14701
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
3
Ownership type
A

19 citations on file for this inspection.

1926.1101 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.1101(g)(1)(ii): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of wet methods or wetting agents to control employee exposures during asbestos handling, mixing, removal, cutting, application and cleanup:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not ensure the use of engineering controls in the form of wet methods or wetting agents to control employee exposures during asbestos removal, cutting, and cleanup.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (S) $2842

1926.1101 H03 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.1101(h)(3)(i)(A): The employer selected or used a filtering facepiece respirator against asbestos fibers.  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019 an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer selected and provided a filtering face piece respirator to use against asbestos fibers.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (S) $3978

1926.1101 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $2,842 · Current $2,842
29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos that exceed the time weighted average and/or excursion limit in 29 CFR 1926.1101(c) or for which a required negative exposure assessment was not produced, or for any employee performing Class I operations which involve the removal of over 25 linear or 10 square feet of TSI or surfacing ACM and PACM.  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is a Class I operation involving the removal of more than 25 linear feet of TSI.  The employer did not provide and require the use of protective clothing such as coveralls or similar whole-body clothing, head coverings, and foot coverings.  The employee was wearing street-clothes while performing the work.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (S) $2842

1926.1101 I02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(i)(2)(i): Asbestos contaminated clothing was not laundered so as to prevent the release of airborne asbestos in excess of the TWA or excursion limit:  a)  55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  Asbestos contaminated clothing worn by the employee was not laundered so as to prevent the airborne release of asbestos in excess of the TWA or excursion limit  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (S) $0

1926.1101 I03

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(i)(3): Contaminated clothing was not transported in sealed impermeable bags, or other closed, impermeable containers, and be labeled in accordance with paragraph (k) of this section:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employee wore street clothes and boots.  Asbestos contaminated clothing worn by the employee was not transported in sealed impermeable bags or other closed impermeable containers.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (S) $0

1926.1101 E01

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(e)(1): All Class I, II, and III asbestos work was not conducted within regulated areas:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  Class I work was not conducted within a regulated area.  The regulated area was not demarcated where Class I asbestos work was performed.   NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 K07 I

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(k)(7)(i): Warning signs that demarcated the regulated area were not provided and displayed at each location where a regulated area was required to be established by paragraph (e) of this section:  a)  55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not provide and display warning signs to demarcate where the regulated area required by paragraph (e) of this section was located.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1926.1101 F02 I

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation or workplace:  a)  55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not conduct an initial exposure assessment to ascertain expected employee exposures to asbestos during this operation.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 G01 III

Willful Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(g)(1)(iii): The employer did not use work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of exposure, in the form of prompt clean-up and disposal of wastes and debris contaminated with asbestos, in leak-tight containers:  a) 55 Jones & Gifford Ave, 2nd floor, storage room - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not ensure that work practices in the form of prompt clean-up and disposal of wastes and debris contaminated with asbestos in leak-tight containers.  Debris was found containing between 21%-35% asbestos.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 G04 II A

Willful Gravity 5 1 instance 2 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(g)(4)(ii)(A): For all Class I jobs involving the removal of more than 25 linear or 10 square feet of thermal system insulation or surfacing material; for other Class I jobs where the employer could not produce a negative exposure assessment pursuant to 29 CFR 1926.1101(f)(2)(iii), or where employees were working in areas adjacent to the regulated area, while the Class I work was being performed, the employer did not use critical barriers placed over all the openings to the regulated area, except where activities were being performed outdoors:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to remove approximately 200 linear feet of pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not use critical barriers over all openings when employees were working adjacent to the regulated area while Class I work was being done.     NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 G04 VI

Willful Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(g)(4)(vi): Regulated areas were not ventilated to move contaminated air toward a HEPA filtration or collection device: Note:  This paragraph applies to Class I operations where the employer cannot produce a negative exposure assessment or where exposure monitoring shows that the PEL is exceeded:  a) 55 Jones & Gifford Ave, 2nd floor -  On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to remove approximately 200 linear feet of pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work subject to the requirements of 29 CFR 1926.1101.  The employer did not ensure the regulated area was ventilated to move contaminated air toward a HEPA filtration system or collection device when a negative exposure assessment for the work was not produced.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1926.1101 G05

Willful Gravity 5 1 instance 3 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(g)(5): Class I asbestos work was not performed using one or more of the control methods required by 29 CFR 1926.1101(g)(5)(i) through (g)(5)(vi) such as negative pressure enclosure (NPE) systems; glove bag system; negative pressure glove bag system; water spray process system; and/or a small walk-in mini-enclosure:   a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, the employer did not ensure that the use of one or more of the required control methods when an employee was instructed to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), using a power saw (i.e. Sawzall), which is Class I asbestos work covered by 29 CFR 1926.1101.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1926.1101 H02 I

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(h)(2)(i): The employer failed to implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) [except (d)(1)(iii)], and (f) through (m), which covers each employee required by 29 CFR 1926.1101 to use a respirator:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work requiring the use of a respirator.  The employer failed to implement a respiratory protection program.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1910.134 E01

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace.  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was required to wear an elastomeric respirator while using a power saw (i.e. Sawzall) to cut and remove a boiler pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM).  The employer did not provide a medical evaluation to determine the employee's ability to use the elastomeric respirator prior to its required use.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1910.134 F01

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employees required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT).   a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was required to wear an elastomeric respirator while using a power saw (i.e. Sawzall) to cut and remove a boiler pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM).  The employer did not ensure that the employee passed an appropriate fit test.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1910.134 K

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k): The employer did not provide effective training to employees who are required to use respirators (Construction Reference 1926.103)  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut and remove a boiler pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is Class I asbestos work requiring the use of a respirator.  The employer did not provide effective training to the employee when respirator use was required.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

1926.1101 J01 I

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(j)(1)(i): The employer did not establish a decontamination area, consisting of an equipment room, shower area, and clean room in series, adjacent and connected to the regulated area: Note:  This requirement applies to Class I operations involving over 25 linear or 10 square feet of thermal system insulation or surfacing containing asbestos-containing material or presumed asbestos-containing material.    a)  55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, the employer did not establish a decontamination area, consisting of an equipment room, shower area, and clean room in series, adjacent and connected to the regulated area when the employer performed Class I asbestos work involving removal of approximately 200 linear feet of asbestos containing material containing between 14%-35% asbestos.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 K03 II B

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $22,730 · Current $22,730
29 CFR 1926.1101(k)(3)(ii)(B): The employer did not inform employees who performed work under 29 CFR 1926.1101 of the location and quantity of asbestos containing material and/or presumed asbestos containing material present in the area:  a) 55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, the employer did not inform employees who performed work under 29 CFR 1926.1101 of the location and quantity of asbestos containing material and/or presumed asbestos containing material present in the area including approximately 200 linear feet of asbestos containing pipe insulation containing between 14% - 35% asbestos.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $22730

1926.1101 K09 I

Willful Gravity 5 1 instance 1 exposed
Issued
Aug 5, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(k)(9)(i): The employer did not institute, at no cost to employees, a training program for each employee who was likely to be exposed in excess of the permissible exposure limit (PEL) and for each employee who performed Class I through IV asbestos operations:  a)  55 Jones & Gifford Ave, 2nd floor - On or about 2/6/2019 - 2/10/2019, an employee was instructed to use a power saw (i.e. Sawzall) to cut pipe covered in Thermal System Insulation (TSI) that was Asbestos Containing Material (ACM), which is a Class I asbestos operation subject to the requirements of 29 CFR 1926.1101.  The employer did not institute a training program for employees performing Class I asbestos operations.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • · Z (W) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343793915.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.