CHICAGO, IL —
OSHA Inspection: ART TYRAWA DBA A & G CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ART TYRAWA DBA A & G CONSTRUCTION in 1747 W. ROSEHILL DR., CHICAGO, IL 60660 (NAICS 238160). OSHA activity number 343800066.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ART TYRAWA DBA A & G CONSTRUCTION
- Site address
- 1747 W. ROSEHILL DR.
- City
- CHICAGO
- State
- IL
- ZIP
- 60660
- Mailing
- 608 CRANDELL LN., SCHAUMBURG, IL 60193
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.150 C01 VI
- Issued
- Aug 12, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $3,410 · Current $2,150 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite: a) On February 21, 2019, a fire extinguisher was not provided where employees were using propane tanks to fuel roofing torches. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2150
- — Z (S) $3410
1926.501 B10
- Issued
- Aug 12, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $3,978 · Current $1,508 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) On February 21, 2019, employees were not protected from the hazard of falling approximately 40 feet above the ground while performing roofing work on a low-sloped roof. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $1508
- — Z (S) $3978
1926.503 A01
- Issued
- Aug 12, 2019
- Abate by
- Sep 13, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) On or about February 21, 2015, employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $2842
- — Z (S) $2842
1926.405 A02 II E
- Issued
- Aug 12, 2019
- Abate by
- Aug 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) On February 21, 2019, the employer did not ensure that the lamps used in temporary wiring to illuminate the work area were protected from accidental contact or breakage. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at ART Tyrawa DBA a & G Construction
View ART Tyrawa DBA a & G Construction's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343800066.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.