Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OSTERMAN PROPANE, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OSTERMAN PROPANE, LLC in 1 BLANCHARD ST, PALMER, MA 01069 (NAICS 454390). OSHA activity number 343801882.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Osterman Propane, LLC — free Get an email when a new federal OSHA severe-injury report for Osterman Propane, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1 BLANCHARD ST
City
PALMER
State
MA
ZIP
01069
Mailing
1 MEMORIAL SQUARE, WHITINSVILLE, MA 01588
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
454390
Employees
250
Ownership type
A

6 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
May 28, 2019
Penalty
Initial $8,525 · Current $5,968 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    1 Blanchard St, Palmer, MA    On February 22, 2019 and at times prior, an employee regularly wore a respirator while spray painting, but had not received a medical evaluation.
Recent events (2)
  • — I (S) $5967.5
  • — Z (S) $8525

1910.134 K05

Serious Gravity 5 1 instance 1 exposed
Issued
May 28, 2019
Abate by
Jul 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(5): the employer did not provide comprehensive, understandable training at least annually for employees who are required to use respirators:    1 Blanchard St, Palmer, MA  On February 22, 2019 and for many years prior, the employer had not provided annual respirator training to an employee who regularly wore a respirator while spray painting.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Serious Gravity 10 1 instance 4 exposed
Issued
May 28, 2019
Abate by
Jul 15, 2019
Penalty
Initial $11,934 · Current $8,354 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:    1 Blanchard St, Palmer, MA    On February 22, 2019 and for many years prior, the employer had not performed oversight inspections of the painter and vehicle mechanic employees to ensure they followed energy control procedures established by the employer and the vehicle manufacturers.  The employer also did not ensure that the inspector annually reviewed with each authorized employee their responsibilities under the employers energy control program.
Recent events (2)
  • — I (S) $8353.8
  • — Z (S) $11934

1910.147 C07 I B

Serious Gravity 10 1 instance 50 exposed
Issued
May 28, 2019
Abate by
Jul 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:   1 Blanchard St, Palmer, MA  On February 22, 2019 at the beginning of the inspection, the employer had not instructed affected employees, including drivers who entered the maintenance shop and operated company vehicles, in the purpose and their responsibilities under the employer's energy control program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I C

Other-than-serious 1 instance 5 exposed
Issued
May 28, 2019
Abate by
Jul 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(C): All other employees whose work operations are or may be in an area where energy control procedures may be utilized, were not instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked out or tagged out.    1 Blanchard St, Palmer, MA    On February 22, 2019 at the beginning of the inspection, the employer had not instructed supervisory and administrative employees about the employer's energy control procedures.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.134 K06

Other-than-serious 1 instance 2 exposed
Issued
May 28, 2019
Abate by
Jul 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    1 Blanchard St, Palmer, MA  On February 22, 2019 at the start of the inspection, the employer had not provided Appendix D information to employees who used non-mandatory respirators, including Gerson 1730 NIOSH N95, filtering facepiece device (FFPD) respirators.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Osterman Propane, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343801882.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.