WASHINGTON, DC —
OSHA Inspection: ROOF WORKS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROOF WORKS INC. in 5614 EASTERN AVE, WASHINGTON, DC 20009 (NAICS 238160). OSHA activity number 343804357.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROOF WORKS INC.
- Site address
- 5614 EASTERN AVE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 9336 ANNAPOLIS ROAD, LANHAM, MD 20706
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Jun 19, 2019
- Penalty
- Initial $1,932 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about February 22, 2019; south-side (rear) of roof; employees were not wearing eye protection while using equipment such as but not limited to hammers to remove the shingles from the roof. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $1000
- — Z (S) $1932
1926.501 B13
- Issued
- Jun 19, 2019
- Penalty
- Initial $3,978 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about February 22, 2019, south-side (rear) of residential build; employees were observed removing the roof of a residential home without fall protection in place to protect them falling approximately 20-25 feet to ground level. No abatement certification or documentation required for this item.
Recent events (2)
- — I (S) $3500
- — Z (S) $3978
1926.1053 B06
- Issued
- Jun 19, 2019
- Abate by
- Jun 25, 2019
- Penalty
- Initial $2,899 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: a) On or about February 22, 2019, south-side (Rear) roof; employees were using an extension ladder to access the roof area was not secured from displacement exposing employees to an estimated 20-25 foot fall hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (2)
- — I (S) $0
- — Z (S) $2899
1926.503 B01
- Issued
- Jun 19, 2019
- Abate by
- Jun 25, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. a) On or about February 22, 2019; the employer had not certified the fall protection training had been provided to employees that were exposed to fall hazards 6-feet or greater while performing roofing work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Roof Works INC.
View Roof Works INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343804357.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.