On , OSHA opened a referral health inspection of THE CINCINNATI STEEL TREATING COMPANY in 5701 MARIEMONT AVENUE, CINCINNATI, OH 45227 (NAICS 332811). OSHA activity number 343805206.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE CINCINNATI STEEL TREATING COMPANY
- Site address
- 5701 MARIEMONT AVENUE
- City
- CINCINNATI
- State
- OH
- ZIP
- 45227
- Mailing
- 5701 MARIEMONT AVENUE, CINCINNATI, OH 45227
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332811
- Employees
- 41
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.28 B06 I
- Issued
- Mar 27, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $9,282 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(6)(i): Each employee less than 4 feet (1.2 m) above dangerous equipment was not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system, unless the equipment is covered or guarded to eliminate the hazard. (a) Employees who worked in the IQ department were exposed to falls into furnaces ranging in temperature from 900 to 1800 degrees F when they were on the catwalk opening and closing the furnace door to place parts into or remove parts from the furnaces. (b) Employees who worked in the IQ department were exposed to falls into the 210 degree F quench tank when quenching aluminum parts that were removed from the 985 degree furnace. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- · I (S) $0
- · Z (S) $9282
1910.132 A
- Issued
- Mar 27, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $9,282 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: (a) On February 26, 2019, the acting shift superintendent was observed wearing a short sleeved t-shirt while unloading parts from a 900 +/- degree F furnace with a crane and opening and closing the furnace lid. (b) On or about February 13, 2019, an employee received third degree burns while wearing shorts under the protective aluminized coat while quenching aluminum from a 985 degree furnace in a 210 degree quench tank. (c) On or about October 26, 2018, the plant superintendent was not wearing safety glasses or a face shield and received second degree facial burns when a flame curtain inside the furnace ignited as the furnace door was opened and the fire flashed on the two employees who were checking to see if the furnace was ready to load from approximately twenty feet away. (d) On or about October 26, 2018, an employee trainee was not wearing safety glasses or a face shield, or a long sleeved 100% cotton uniform shirt and received second degree burns to the face, neck and upper chest, when a flame curtain inside the furnace ignited as the furnace door was opened and the fire flashed on the two employees who were checking to see if the furnace was ready to load from approximately ten feet away. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- · I (S) $0
- · Z (S) $9282
1910.132 D01 I
- Issued
- Mar 27, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $0 · Current $5,569
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: (a) The employer did not enforce the use of appropriate personal protective equipment to protect employees from workplace hazards that were identified in the initial hazard assessment. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- · I (S) $5569
- · Z (S) $0
1910.132 D02
- Issued
- Mar 27, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment: (a) The employer did not certify in writing that a workplace hazard assessment had been completed. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.