CEDAR PARK, TX ·
OSHA Inspection: S & M BUSINESSES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of S & M BUSINESSES, INC. in 3875 WHITESTONE BLVD., CEDAR PARK, TX 78613 (NAICS 321999). OSHA activity number 343805313.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- S & M BUSINESSES, INC.
- Site address
- 3875 WHITESTONE BLVD.
- City
- CEDAR PARK
- State
- TX
- ZIP
- 78613
- Mailing
- 3875 WHITESTONE BLVD., CEDAR PARK, TX 78613
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 150
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Mar 28, 2019
- Abate by
- Apr 16, 2019
- Penalty
- Initial $11,934 · Current $11,934
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about February 20, 2019, and at times prior thereto, employees were performing maintenance on the wheel loader machine troubleshooting a hydraulic leak with the boom raised without establishing an energy control program, exposing employees to the hazard of being crushed by the boom.
Recent events (2)
- · I (S) $11934
- · Z (S) $11934
1910.147 C05 I
- Issued
- Mar 28, 2019
- Abate by
- Apr 3, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: On or about February 20, 2018, and at times prior thereto, energy isolating devices were not used to protect employees from hazardous energy such as but not limited to hydraulic, kinetic potential, exposing employees to the hazard of being struck by or crushed by the machine.
Recent events (2)
- · I (S) $0
- · Z (S) $11934
More inspections in this industry (NAICS 321999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343805313.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.