DALLAS, TX —
OSHA Inspection: DANIEL TINAJERO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DANIEL TINAJERO in 3700 MIRAMAR AVE, DALLAS, TX 75205 (NAICS 238140). OSHA activity number 343808168.
Where did this inspection happen?
- Establishment
- DANIEL TINAJERO
- Site address
- 3700 MIRAMAR AVE
- City
- DALLAS
- State
- TX
- ZIP
- 75205
- Mailing
- 514 N KAUFMAN ST, SEAGOVILLE, TX 75159
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2387.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: On or about February 25, 2019. Employees were exposed to a fall hazard of approximately 13 feet in height while working on a 3 tier scaffold with missing planks.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2387.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. On or about February 25, 2019. Employees were exposed to a fall hazard of approximately 13 feet in height while working on a 3 tier scaffold and using side panels as means of access and egress.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $3978.00 · Current $2387.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. On or about February 25, 2019. Employees were exposed to a fall hazard of approximately 13 feet in height while working on a 3 tier scaffold without guard rails on the open ends.
Recent events (2)
- — I (S) $2386.8
- — Z (S) $3978
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343808168.