SYRACUSE, NY —
OSHA Inspection: TPSTYLES INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of TPSTYLES INC. in 1 GENERAL MOTORS DRIVE, BLDG 912, SYRACUSE, NY 13206 (NAICS 337110). OSHA activity number 343810867.
Where did this inspection happen?
- Establishment
- TPSTYLES INC.
- Site address
- 1 GENERAL MOTORS DRIVE, BLDG 912
- City
- SYRACUSE
- State
- NY
- ZIP
- 13206
- Mailing
- PO BOX 797, SYRACUSE, NY 13206
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 20
- Ownership type
- A
Citations
14 citations on file for this inspection.
1910.22 A01
- Issued
- Jul 9, 2019
- Penalty
- Initial $1,932 · Current $1,352 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): Place(s) of employment were not kept clean: a) Fabrication Area, on or about 2/22/19: Explosive Wood Dust (Class II) was observed throughout the floor in the area where saw operations were taking place.
Recent events (2)
- — I (S) $1352.4
- — Z (S) $1932
1910.106 E06 I
- Issued
- Jul 9, 2019
- Penalty
- Initial $1,932 · Current $1,352 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: a) Spray Area, on or about 2/22/19: Employees dispensing a Category 2 Flammable Liquid, Astro Chemical Thinner without grounding the 55 gallon container. b) Spray Area, on or about 2/22/19: Employees adding material to a 55 gallon drum of flammable waste without grounding the 55 gallon container.
Recent events (2)
- — I (S) $1352.4
- — Z (S) $1932
1910.106 E06 II
- Issued
- Jul 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Spray Area, on or about 2/22/19: Employees dispense a Category 2 Flammable Liquid: Astro Chemical Thinner from a 55 gallon container to a secondary container with no means of electrically interconnecting the nozzle and the portable container. b) Spray Area, on or about 2/22/19: Employees dispense flammable waste from containers into a 55 gallon container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Jul 9, 2019
- Penalty
- Initial $1,932 · Current $1,352 Reduced
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s): a) Spray Area, on or about 2/22/19: Combustible materials including but not limited to: Twelve five gallon containers of flammable materials and a wood table were observed being stored on the right side of the paint booth.
Recent events (2)
- — I (S) $1352.4
- — Z (S) $1932
1910.134 C02 I
- Issued
- Jul 9, 2019
- Penalty
- Initial $2,273 · Current $1,591 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): When voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section: a) Throughout the workplace, on or about 2/22/19: Employer allows voluntary use of dust masks and has not supplied employees with Appendix D of the respirator standard.
Recent events (2)
- — I (S) $1591.1
- — Z (S) $2273
1910.134 E01
- Issued
- Jul 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Spray Area, on or about 2/22/19: Employees wear 3M half face air purifying respirators and had not been provided with a medical evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Jul 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Spray Area, on or about 2/22/19: Employees required to wear 3M half face air purifying respirators had not been fit tested
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Jul 9, 2019
- Penalty
- Initial $3,789 · Current $2,652 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Throughout the facility, on or about 4/11/19: Specific procedures were not developed or written for employees who perform servicing and/or maintenance on various machinery or equipment including but not limited to: Biesse CNC Router and Ayen Boring Machine.
Recent events (2)
- — I (S) $2652.3
- — Z (S) $3789
1910.157 G02
- Issued
- Jul 9, 2019
- Penalty
- Initial $2,273 · Current $1,591 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Throughout the facility, on or about 4/11/19: Training was not provided to employees annually on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. Last training conducted was January 16, 2017. * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39 which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
- — I (S) $1591.1
- — Z (S) $2273
1910.242 B
- Issued
- Jul 9, 2019
- Penalty
- Initial $2,576 · Current $1,803 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Fabrication Area, on or about 2/22/19: Employee used compressed air for cleaning purposes was measured at approximately 118 p.s.i.
Recent events (2)
- — I (S) $1803.2
- — Z (S) $2576
1910.1052 D02
- Issued
- Jul 9, 2019
- Penalty
- Initial $2,273 · Current $1,591 Reduced
1730
General-duty citation text
29 CFR 1910.1052(d)(2) Employer had employees exposed to methylene chloride and did not perform initial exposure monitoring to determine each affected employee's exposure: a)Assembly Area, on or about 5/1/19: Employer had not conducted initial monitoring to assess employee exposure to methylene chloride. Employee sprays contact adhesive containing methylene chloride when making wall panels.
Recent events (2)
- — I (S) $1591.1
- — Z (S) $2273
1910.1052 L01
- Issued
- Jul 9, 2019
- Abate by
- Jul 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride: a) Assembly Area, on or about 5/1/19: Employees work with a contact adhesive containing methylene chloride. Employer had not provided information and training prior to the start of their assignment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.106 D03 II A
- Issued
- Jul 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.106(d)(3)(ii)(a): Metal cabinets constructed in the following manner shall be deemed to be in compliance. The door shall be provided with a three pointed lock. a) Spray Area, on or about 2/22/19: Metal cabinet was not deemed to be incompliance in that the door was not provided with a working three point lock.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Jul 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Throughout the facility, on or about 4/11/19: The employer had not provided an evaluation of each powered industrial truck operator at least once every three years.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Tpstyles INC.
View Tpstyles INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343810867.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.