OSHA Inspection: MPZ MASONRY AND CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MPZ MASONRY AND CONSTRUCTION, INC. in 8955 N. GREENWOOD AVE., NILES, IL 60714 (NAICS 238140). OSHA activity number 343810875.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MPZ Masonry and Construction, INC. — free Get an email when a new federal OSHA severe-injury report for MPZ Masonry and Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8955 N. GREENWOOD AVE.
City
NILES
State
IL
ZIP
60714
Mailing
5134 N. ELSTON AVE., CHICAGO, IL 60630
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 6, 2019
Abate by
Mar 12, 2019
Penalty
Initial $5,304 · Current $3,333 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports:        a) On or about February 26, 2019, employees were exposed to the hazard of falling approximately 25 feet while working from scaffolding that was not fully planked.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3333.33
  • — Z (S) $5304

1926.451 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 6, 2019
Abate by
Mar 12, 2019
Penalty
Initial $5,304 · Current $3,333 Reduced
29 CFR 1926.451(e)(1): Safe access was not provided to scaffold platforms when the platforms were more than 2 feet (0.6 m) above or below a point of access:            a) On or about February 26, 2019, employees were exposed to the hazard of falling from elevations up to approximately 25 feet where safe access to scaffold platforms was not provided.        In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3333.33
  • — Z (S) $5304

1926.451 G01

Serious Gravity 10 8 instances 6 exposed
Issued
Mar 6, 2019
Abate by
Mar 12, 2019
Penalty
Initial $5,304 · Current $3,333 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level:              a) On or about February 26, 2019, employees were exposed to the hazard of falling from elevations of between 14 and 25 feet while working from scaffolding without guardrail systems or other fall protection.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $3333.34
  • — Z (S) $5304

1926.501 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Mar 6, 2019
Abate by
Mar 12, 2019
Penalty
Initial $5,304 · Current $0 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:         a) On or about February 26, 2019, employees were exposed to the hazard of falling approximately 15 feet while walking/working at and along an unprotected edge of a roof deck.          In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5304