SOUTH PORTLAND, ME ·
OSHA Inspection: QUICK PLUG NA, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of QUICK PLUG NA, INC. in 165 PLEASANT AVE. UNIT B, SOUTH PORTLAND, ME 04106 (NAICS 115112). OSHA activity number 343811881.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUICK PLUG NA, INC.
- Site address
- 165 PLEASANT AVE. UNIT B
- City
- SOUTH PORTLAND
- State
- ME
- ZIP
- 04106
- Mailing
- 165 PLEASANT AVE. UNIT B, SOUTH PORTLAND, ME 04106
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 115112
- Employees
- 40
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- May 20, 2019
- Abate by
- Jul 8, 2019
- Penalty
- Initial $4,508 · Current $2,254 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: Carousel Area - The working area was not free of trip hazards such as, but not limited to, debris, cable/hose near the front of the carousel.
Recent events (3)
- · F (S) $2254
- · C (S) $4508
- · Z (S) $4508
1910.132 D01 I
- Issued
- May 20, 2019
- Penalty
- Initial $5,635 · Current $2,818 Reduced
General-duty citation text
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Carousel Area - The Employer did not select appropriate gloves or ensure an effective change schedule for employees using nitrile gloves while moving molds with media saturated in toluene diisocyanate prepolymer, resulting in hazardous chemical break-through.
Recent events (3)
- · F (S) $2818
- · C (S) $5635
- · Z (S) $5635
1910.178 Q07
- Issued
- May 20, 2019
- Penalty
- Initial $5,635 · Current $2,817 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: Establishment - The employer did not ensure that Toyota forklifts with serial numbers 11850 and 38740, received a daily check for defects prior to second shift use.
Recent events (3)
- · F (S) $2817
- · C (S) $5635
- · Z (S) $5635
1910.1200 H01
- Issued
- May 20, 2019
- Penalty
- Initial $5,635 · Current $2,817 Reduced
2470T177
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: Establishment - Employees were not provided effective information or training prior to initial work assignment regarding the sections of a safety data sheet, labeling requirements, and pictograms prior to working with hazardous chemicals such as but not limited to toluene diisocyanate prepolymer.
Recent events (3)
- · F (S) $2817
- · C (S) $5635
- · Z (S) $5635
1910.134 K06
- Issued
- May 20, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: Establishment - The employer did not provide information regarding respirators, as presented in Appendix D of 29 CFR 1910.134, to employees using company provided respirators on a voluntary basis.