HOUSTON, TX ·
OSHA Inspection: STINGER CHEMICAL
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of STINGER CHEMICAL in 905 LIVE OAK, HOUSTON, TX 77003 (NAICS 324191). OSHA activity number 343821690.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STINGER CHEMICAL
- Site address
- 905 LIVE OAK
- City
- HOUSTON
- State
- TX
- ZIP
- 77003
- Mailing
- 905 LIVE OAK, HOUSTON, TX 77003
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324191
- Employees
- 35
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.28 B11 II
- Issued
- May 2, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Stairways. The employer did not ensure each flight of stairs having at least 3 treads and at least 4 risers was equipped with stair rail systems and handrails per Table D-2; stair width less than 44 inches (1.1 m), and one open sides required to have one stair rail system on each open side: a) On or about March 1, 2019 in the blending area, a stairway used by employees to access the blending platform did not have a midrail, exposing employees to a fall hazard. b) On or about March 1, 2019 in the back dock area, a stairway used by employees did not have a stair rail system exposing employees to a fall hazard.
Recent events (2)
- · I (S) $2386.8
- · Z (S) $3978
1910.134 C01
- Issued
- May 2, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) On or about March 1, 2019 in the blending area, a respiratory program had not been developed for employees using full face elastomeric respirators while blending; exposing employees to inhalation hazards.
Recent events (2)
- · I (S) $2386.8
- · Z (S) $3978
1910.134 K
- Issued
- May 2, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k): The employer did not provided effective training to employees who are required to use respirators: a) On or about March 1, 2019 in the blending area, respirator training had not been conducted for employees using full face elastomeric respirators while blending; exposing employees to inhalation hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 E01
- Issued
- May 2, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) On or about March 1, 2019 in the blending area, employees using full face elastomeric respirators while blending had not been medically evaluated exposing employees to inhalation hazards.
Recent events (2)
- · I (S) $2386.8
- · Z (S) $3978
1910.134 F01
- Issued
- May 2, 2019
- Abate by
- Aug 1, 2019
- Penalty
- Initial $3,978 · Current $2,387 Reduced
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator passed an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) On or about March 1, 2019 in the blending area, employees using full face elastomeric respirators while blending had not been fit tested exposing employees to inhalation hazards.
Recent events (2)
- · I (S) $2386.8
- · Z (S) $3978
More inspections in this industry (NAICS 324191)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343821690.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.