Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUOR INDUSTRIAL SERVICES, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FLUOR INDUSTRIAL SERVICES, INC. in 9978 FM 3129, QUEEN CITY, TX 75572 (NAICS 561210). OSHA activity number 343822300.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fluor Industrial Services, INC. — free Get an email when a new federal OSHA severe-injury report for Fluor Industrial Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
9978 FM 3129
City
QUEEN CITY
State
TX
ZIP
75572
Mailing
9978 FM 3129, QUEEN CITY, TX 75572
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561210
Employees
85
Ownership type
A

4 citations on file for this inspection.

1910.133 A01

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 11, 2019
Abate by
Aug 27, 2019
Penalty
Initial $9,472 · Current $0 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a) On or about November 29, 2018 the employer did not ensure that employees erecting a barrier on the blowdown line in the powerhouse located at 9978 FM RD. 3129, Queen City, TX 75572 used appropriate face protection to protect them from unexpected releases of 212 degree steam.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9472

1910.138 A

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 11, 2019
Abate by
Aug 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:  (a) On or about November 29 2018 the employer did not select and require employees to use thermally resistant hand protection while employees were erecting a barrier for the blowdown header in the powerhouse located at 9978 FM RD. 3129, Queen City, TX 75572, exposing employees to burns from 212 degree steam.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 11, 2019
Abate by
Aug 27, 2019
Penalty
Initial $9,472 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) On February 27, 2019 and at times prior thereto the employer did not included a process for developing, documents and utilizing specific energy control procedures in their energy control program, exposing employees to hazards associated with unexpected releases of hazardous energy;  (b) On or about November 29, 2018 the employer did not develop specific energy control procedures for erecting a barrier on a blow down header in the powerhouse located at 9978 FM Rd, 3129, Queen City, TX 75572, exposing employees to second and third degree burns from steam.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9472

1910.147 D04 I

Deleted Serious Gravity 5 1 instance 5 exposed
Issued
Jul 11, 2019
Abate by
Aug 27, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) On or about November 29, 2018 the employer did not ensure that lockout devices were affixed to all sources of hazardous energy while erecting a barrier in the powerhouse located at 9978 FM RD. 3129, Queen City, TX 75572, exposing employees to burns associated with the unexpected release of thermal energy.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Fluor Industrial Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343822300.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.