PANAMA CITY, FL ·
OSHA Inspection: PACHECO INTERIOR DESIGN, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PACHECO INTERIOR DESIGN, INC. in 650 WEST 23RD STREET SUITE 626 EXTERIOR, PANAMA CITY, FL 32405 (NAICS 238350). OSHA activity number 343822839.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACHECO INTERIOR DESIGN, INC.
- Site address
- 650 WEST 23RD STREET SUITE 626 EXTERIOR
- City
- PANAMA CITY
- State
- FL
- ZIP
- 32405
- Mailing
- 1693 RIDGEMOOR DRIVE, MASCOTTE, FL 34753
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 20
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.501 B01
- Issued
- Aug 21, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall protection system: a. On or about February 27, 2019, employee's working taking measurements and installing plywood wall trim, standing on partially decked plywood decking with unprotected sides between the truss/rafter cross braces without the use of a properly connected fall protection system, being exposed to a 10-foot 6-inch fall hazard. One employee had disconnected to reposition retractable fell sustained fracture and resulted in hospitalization.
Recent events (2)
- · I (S) $5569.2
- · Z (S) $9282
1926.503 A02
- Issued
- Aug 21, 2019
- Abate by
- Oct 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2): The employer did not assure that each employee exposed to fall hazards was trained by a competent person qualified in the areas specified in 29 CFR 1926.503 (a)(2)(i) through (viii): a. On or about February 27, 2019, employee's worked taking measurements and installing plywood wall trim, standing on partially decked plywood decking with unprotected sides between the truss/rafter cross braces 10-foot 6-inch above the concrete walkway without the use of a properly connected fall protection systems, the employer and employees were not adequately trained by a competent person in the use of personal fall protection systems and were exposed to injuries from fall hazards.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 238350)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343822839.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.