OSHA Inspection: EVERON POLYMERS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EVERON POLYMERS, LLC in 420 WOODRUFF RD., JOLIET, IL 60403 (NAICS 423930). OSHA activity number 343825345.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Everon Polymers, LLC for free Get an email when a new federal OSHA severe-injury report for Everon Polymers, LLC is published. One employer, no account, unsubscribe in one click.
Site address
420 WOODRUFF RD.
City
JOLIET
State
IL
ZIP
60403
Mailing
420 WOODRUFF RD., JOLIET, IL 60403
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423930
Employees
5
Ownership type
A

5 citations on file for this inspection.

1910.176 B

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 21, 2019
Abate by
Apr 16, 2019
Penalty
Initial $1,705 · Current $1,023 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse:     a.  On or about March 5, 2019, in the warehouse area, cardboard gaylords on pallets were stacked four high and were not interlocked or secured.  The gaylords were unstable and in a corner of the warehouse several had fallen and others were not secure. Employees working in the warehouse were exposed to struck-by hazards.
Recent events (2)
  • · I (S) $1023
  • · Z (S) $1705

1910.178 L01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 21, 2019
Abate by
May 1, 2019
Penalty
Initial $1,705 · Current $1,023 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a. On or about March 5, 2019, in the warehouse, employees were required to operate forklifts.  The employer did not ensure affected employees were trained and evaluated to operate the forklifts in a safe manner.
Recent events (2)
  • · I (S) $1023
  • · Z (S) $1705

1910.178 P01

Serious Gravity 1 1 instance 3 exposed
Issued
Mar 21, 2019
Abate by
May 1, 2019
Penalty
Initial $1,705 · Current $954 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s):    a.  On or about March 5, 2019, in the warehouse, the employer had not taken defective powered industrial trucks (forklifts) that were missing the propane tank latches out of service until they had been restored to a safe operating condition. Employees were thereby exposed to the hazards of an unsecured propane tank.
Recent events (2)
  • · I (S) $954
  • · Z (S) $1705

1910.37 A03

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2019
Abate by
Jun 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    a. On or about March 5, 2019, in the warehouse, the side exit door was locked closed with a bar, thereby exposing employees to the hazards of fire and smoke inhalation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.37 A04

Other-than-serious 1 instance 3 exposed
Issued
Mar 21, 2019
Abate by
May 1, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:    a. On or about March 5, 2019, in the warehouse, the exit sign over the side exit door was not illuminated by a reliable light source, thereby exposing employees to the hazards of fire and smoke inhalation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343825345.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.