SAN ANTONIO, TX —
OSHA Inspection: UNIVERSITY HEALTH SYSTEM
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of UNIVERSITY HEALTH SYSTEM in 4502 MEDICAL DR, SAN ANTONIO, TX 78229 (NAICS 622110). OSHA activity number 343827440.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNIVERSITY HEALTH SYSTEM
- Site address
- 4502 MEDICAL DR
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78229
- Mailing
- 4502 MEDICAL DR, SAN ANTONIO, TX 78229
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 622110
- Employees
- 8000
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.28 B01 I
- Issued
- Jun 6, 2019
- Abate by
- Jun 26, 2019
- Penalty
- Initial $7,577 · Current $4,546 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: On or about February 27, 2019, and at times prior thereto, employees were exposed to fall hazards greater than 4ft while repairing valves and pipes on top of boilers without fall protection.
Recent events (2)
- — I (S) $4546.2
- — Z (S) $7577
1910.28 B03 I A
- Issued
- Jun 6, 2019
- Abate by
- Jun 26, 2019
- Penalty
- Initial $7,577 · Current $4,546 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(i)(A): The employer did not ensure that each employee on a walking-working surface was protected from falling into any hole or pit that was 4 feet (1.2 m) or more above a lower level by a cover: On or about February 27, 2019, and at times prior thereto, employees were exposed to a fall hazard while working around an open sump pump without grating.
Recent events (2)
- — I (S) $4546.2
- — Z (S) $7577
1910.146 D03
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $7,577 · Current $4,546 Reduced
General-duty citation text
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including, but not limited to items (d)(3)(i) through (d)(3)(vi) of this paragraph. A) On or about February 27, 2019, and at times prior thereto, employees entered confined spaces such as, but not limited to water boilers and sump pumps without the means, procedures, and work practices for safe permit required confined space entry.
Recent events (2)
- — I (S) $4546.2
- — Z (S) $7577
1910.146 C02
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: A) On or about February 27, 2019, and at times prior thereto, the employer did not have signage demarcating the water boilers as a permit required confined spaces. B) On or about February 27, 2019, and at times prior thereto, the employer did not have signage demarcating the sump area as a permit required confined spaces.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C04 I
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $11,366 · Current $6,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: A) University Health Systems - On or about February 28, 2019, and at times prior thereto, employees were exposed to struck by hazards while repairing valves on boilers without access to equipment specific energy control procedures B) University Health Systems - On or about February 28, 2019, and at times prior thereto, employees were exposed to caught in hazards while repairing chillers without access to equipment specific energy control procedures
Recent events (2)
- — I (S) $6819.6
- — Z (S) $11366
1910.147 C06 I
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: University Health Systems - On or about February 28, 2019, and at times prior thereto, the employer did not perform periodic inspections of the energy control program since 2016
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: On or about February 27, 2019, and at times prior thereto, employees performed energy control procedures on equipment such as, but not limited to water boilers and chillers without receiving training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Jun 6, 2019
- Abate by
- Jul 11, 2019
- Penalty
- Initial $5,683 · Current $3,410 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): Plant area: On or about February 27, 2019, and at times prior thereto, employees were exposed to chemical hazards such as, but not limited to sulfuric acid while performing maintenance and repairs on the water boiler system without implementation of a hazard communication program to address key issues of hazardous chemicals and materials such as, but not limited to, training, necessary personal protective equipment, handling and non-routine tasks.
Recent events (2)
- — I (S) $3409.8
- — Z (S) $5683
More inspections at University Health System
View University Health System's full OSHA safety record →
More inspections in this industry (NAICS 622110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343827440.