EDISON, NJ —
OSHA Inspection: NEWARK WIRE WORKS INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NEWARK WIRE WORKS INC. in 1059 KING GEORGES POST RD., EDISON, NJ 08837 (NAICS 332618). OSHA activity number 343830774.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEWARK WIRE WORKS INC.
- Site address
- 1059 KING GEORGES POST RD.
- City
- EDISON
- State
- NJ
- ZIP
- 08837
- Mailing
- 1059 KING GEORGES POST RD., EDISON, NJ 08837
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332618
- Employees
- 25
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.22 A01
- Issued
- Aug 27, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the facility: The employer did not ensure that walking-working surfaces were kept in a clean, orderly, and sanitary condition. a) Paint booth Area- The employer did not ensure that painting area was cleaned. Employees walked and worked in area where flammable layer of over spray accumulated on the floor. b) Welding and Grinding Area- The employer did not ensure that metal dust was cleaned up from the tables and floors. c) Metal cutting Area- The employer did not ensure that water which accumulated as a result of a rain, was cleaned up promptly. Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $1819
- — C (S) $3031
- — Z (S) $3031
1910.37 B06
- Issued
- Aug 27, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color: a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- The side storage room: The employer did not ensure that all exits in the facility were maintained and in working condition, to be clearly visible at all times. Emergency exit light was not working. Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $1364
- — C (S) $2273
- — Z (S) $2273
1910.107 C05
- Issued
- Aug 27, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.107(c)(5): Electrical equipment not approved for locations containing both deposits of readily ignitable residues and explosive vapors was present in spraying area(s): a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Spray Booth/Spray Painting Area: The employer did not ensure that all electrical equipment including lights was approved for locations containing explosive vapors. Condition noted on or about March 6, 2019.
Recent events (3)
- — R (S) $1819
- — C (S) $3031
- — Z (S) $3031
1910.107 B05 I
- Issued
- Aug 27, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained: a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Spray Booth/Spray Painting Area: The employer did not install in the spray booth with visible gauges, audible alarms or pressure activated devices to indicate or ensure that the required air speed was maintained. Employees were using spray booth to paint metal cages. Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Aug 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet on all sides was not kept free from storage or combustible construction: a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Spray Booth/Spray Painting Area: The lateral walls around the paint spray booth were used for storing materials such as but not limited to metal pieces for cages. Condition noted on or about March 6, 2019.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Aug 27, 2019
- Penalty
- Initial $2,273 · Current $1,364 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Painting Area: The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for employees required to wear: a) 3M elastomeric half face, filtering face piece respirator b) 3M full face respirator Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $1364
- — C (S) $2273
- — Z (S) $2273
1910.134 E01
- Issued
- Aug 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or was required to use the respirator in the workplace: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Employer did not provide medical evaluation to determine that employees were medically fit to wear respirators. Respirators used during spray painting operations included: a) 3M elastomeric half face, filtering face piece respirator b) 3M full face respirator Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 K03
- Issued
- Aug 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Painting Area: The employer did not provide comprehensive training to employees who were required to use respirators at the work place. Respirators used on included: a) 3M elastomeric half face, filtering face piece respirator b) 3M full face respirator Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Aug 27, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $3,789 · Current $2,272 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Cutting/Punching Area: The employer did not ensure that a guard was installed at or near the point of operation for the equipment used on site. Some of the equipment was operated/activated by a pedal. Employees were exposed to amputations, when they used the following: a) Niagara (IB 36-6-8) press break b) Piranha (green) punch press c) KMT Saw Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $2272
- — C (S) $3789
- — Z (S) $3789
1910.217 B04 I
- Issued
- Aug 27, 2019
- Abate by
- Sep 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Cutting/Punching Area: The employer did not ensure that a guard was installed on the pedal in order to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedal and activating the following machines: a) Niagara (IB 36-6-8) press break b) Piranha (green) punch press Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $0
- — C (S) $0
- — Z (S) $0
1910.252 B02 III
- Issued
- Aug 27, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles, to protect them from the rays when noncombustible or flameproof screens or shields were not used: a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Welding Area: The employer did not supply welding screens, where employees performed metal inert gas (MIG) welding. Employees working and walking adjacent to the operations were not protected from the welding rays. Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $1819
- — C (S) $3031
- — Z (S) $3031
1910.1200 H01
- Issued
- Aug 27, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Newark Wire Works Inc./1059 King Georges Post Rd. Edison, NJ- Throughout the Facility including Welding and Painting Area: The employer did not provide hazardous chemical training for employees engaged in manufacturing of welded wire mesh partitions and storage lockers. Employees were required weld, grind and paint metal pieces exposing them to metal dust, fumes and toxic vapors. Employees used chemical products containing chemicals such as, but not limited to: xylene, ethylbenzene, naphtha, toluene, iron and manganese. Condition observed on or about March 6, 2019.
Recent events (3)
- — R (S) $1819
- — C (S) $3031
- — Z (S) $3031
More inspections at Newark Wire Works INC.
View Newark Wire Works INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332618)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343830774.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.