Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A.G.R. CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A.G.R. CONSTRUCTION, LLC in JAMISON STREET NE, WASHINGTON, DC 20018 (NAICS 238130). OSHA activity number 343830873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A.G.R. Construction, LLC — free Get an email when a new federal OSHA severe-injury report for A.G.R. Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
JAMISON STREET NE
City
WASHINGTON
State
DC
ZIP
20018
Mailing
11628 LOCKWOOD DR APT 104, SILVER SPRING, MD 20904
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 23, 2019
Abate by
Aug 29, 2019
Penalty
Initial $4,376 · Current $4,376
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about February 26, 2019, northeast corner of residential building; employees were observed framing of a residential home under construction without fall protection in place to protect them falling an estimated 35-40 feet to ground level.     In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification.  This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4376

1926.1053 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Aug 23, 2019
Penalty
Initial $3,188 · Current $3,188
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On or about February 26, 2019, north-side front; employees were using an extension ladder to access the third floor with the side rails extended 18-inches above the landing surface, exposing employees to an estimated 20-foot fall.     b) On or about February 26, 2019, third floor west-side area; employees were using a step-ladder to access the upper floor area with the side rails extended 4-feet below the landing surface, exposing employees to an estimated 10-foot fall to the wooden deck area.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (1)
  • — Z (S) $3188

1926.1053 B06

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 23, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level:  a) On or about February 26, 2019, north-side front; employees were using an extension ladder to access the  floor third area that was not secured from displacement exposing employees to an estimated 20-foot fall hazard; ladder was set on uneven dirt surface.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 23, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step   a) On or about February 26, 2019; Third floor; employees were using a six foot step ladder to access the roof area that was too short for the application; 4-feet below the working platform.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet.
Recent events (1)
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 6 exposed
Issued
Aug 23, 2019
Abate by
Aug 29, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about February 26, 2019; the employer had not certified the fall protection training to employees that were exposed to fall hazards 6-feet or greater while performing framing operations.   In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
  • — Z (O) $0

View A.G.R. Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343830873.