Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PATRIOT TIRE SHREDDERS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PATRIOT TIRE SHREDDERS in 147 SOUTH 15TH STREET, EAST SAINT LOUIS, IL 62205 (NAICS 326299). OSHA activity number 343832994.

Watch Patriot Tire Shredders — free Get an email when a new federal OSHA severe-injury report for Patriot Tire Shredders is published. One employer, no account, unsubscribe in one click.
Site address
147 SOUTH 15TH STREET
City
EAST SAINT LOUIS
State
IL
ZIP
62205
Mailing
147 SOUTH 15TH STREET, EAST SAINT LOUIS, IL 62205
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326299
Employees
5
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     The employer did not established an energy control program (Lockout/Tagout Program) consisting of energy control procedures, employee training and periodic inspections.  Employees conduct service and maintenance on equipment such as, but not limited to, the tire shredder.
Recent events (3)
  • — A (S) $3978
  • — I (S) $2785
  • — Z (S) $3978

1910.219 C03

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2842.00 · Current $2842.00
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s):     The tire shredder machine drive shaft and coupling was not enclosed.
Recent events (3)
  • — A (S) $2842
  • — I (S) $1705
  • — Z (S) $2842

1910.305 D02

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3978.00 · Current $3978.00
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets that were dead front:    400 Volt electrical cabinets located in the equipment storage area did not have dead front panel's installed, exposing energized components.
Recent events (3)
  • — A (S) $3978
  • — I (S) $2387
  • — Z (S) $3978

1910.305 G01 IV A

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:     In the equipment room an extension cord was used as a substitute for fixed wiring.  The extension cord was directly connected to a circuit breaker, in the circuit breaker box, to provide power for a portable light stand.
Recent events (3)
  • — A (S) $2273
  • — I (S) $1364
  • — Z (S) $2273

1910.334 A02 I

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $3410.00 · Current $3410.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):    Flexible cord sets (extension cords) in use throughout the facility were not visually inspected before use for defects and damage.
Recent events (3)
  • — A (S) $3410
  • — I (S) $2046
  • — Z (S) $3410

1910.334 A02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  An extension cord, located in the equipment room, was damaged and not removed from service.  The cord outer jacket was cut/torn exposing the internal current carrying wires.
Recent events (3)
  • — A (S) $0
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343832994.