Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: QUALITY FABRICATION & MACHINE WORKS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of QUALITY FABRICATION & MACHINE WORKS, INC. in 3631 E US HWY 90, LAKE CITY, FL 32055 (NAICS 331110). OSHA activity number 343833430.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Quality Fabrication & Machine Works, INC. — free Get an email when a new federal OSHA severe-injury report for Quality Fabrication & Machine Works, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3631 E US HWY 90
City
LAKE CITY
State
FL
ZIP
32055
Mailing
3631 E US HWY 90, LAKE CITY, FL 32055
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331110
Employees
75
Ownership type
A

6 citations on file for this inspection.

1910.95 C01

Serious Gravity 1 1 instance 25 exposed
Issued
May 21, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced

Hazardous substances 81118130

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  a. On or about March 7, 2019, in the in the fabrication area, a welder was exposed to a noise dose of 73%, or an equivalent of 87.8 dBA, as sampling was performed for 410 minutes during one shift on February 7, 2019. The employer failed to administer an effective and continuing hearing conservation program.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.95 D01

Serious Gravity 1 1 instance 1 exposed
Issued
May 21, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 81118130

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:  a. On or about March 7, 2019, in the in the fabrication area, a welder was exposed to a noise dose of 73%, or an equivalent of 87.8 dBA, as sampling was performed for 410 minutes during one shift on February 7, 2019. The employer failed to implement an effective and continuous monitoring program.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G05 II

Serious Gravity 1 1 instance 25 exposed
Issued
May 21, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 81118130

29 CFR 1910.95(g)(5)(ii): Where mobile test vans were used to meet the audiometric testing obligation, the employer did not obtain a valid baseline audiogram within 1 year of an employee's first exposure at or above the action level:  a. On or about March 7, 2019, in the in the fabrication area, a welder was exposed to a noise dose of 73%, or an equivalent of 87.8 dBA, as sampling was performed for 410 minutes during one shift on February 7, 2019. The employer failed to conduct baseline hearing test to exposed employees within one year above the action level.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G06

Serious Gravity 1 3 instances 25 exposed
Issued
May 21, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 81118130

29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels :  a. On or about March 7, 2019, in the in the fabrication area, a welder was exposed to a noise dose of 73%, or an equivalent of 87.8 dBA, as sampling was performed for 410 minutes during one shift on February 7, 2019. The employer failed to conduct yearly hearing test to exposed employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.133 A05

Serious Gravity 1 1 instance 1 exposed
Issued
May 21, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced

Hazardous substances 8370

29 CFR 1910.133(a)(5): The employer did not ensure that each affected employee used equipment with filter lenses that had a shade number appropriate for the work being performed for protection from injurious light radiation.  a) On or about February 7, 2019, in the plasma cutting area, the employer failed to ensure that employee operating a "Hypertherm Powermax 105" plasma arc cutting equipment and exposed to UV light was protected against radiant energy by using appropriate shade numbers filter lenses. Employee operating equipment plasma arc cutting equipment used dark color safety glasses without a shade number.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.252 B02 III

Other-than-serious 1 instance 25 exposed
Issued
May 21, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 8370

29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  a) On or about February 7, 2019, in the general fabrication area, the employer failed to ensure that employees working in areas adjacent where welding operations were conducted with metal inert gas (MIG) equipment were protected from exposure to UV light and against radiant energy by enclosing the operation with noncombustible or flameproof screens or shields.   b) On or about February 7, 2019, in the general fabrication area, the employer failed to ensure that employees working in areas adjacent to the plasma cutter operations (Hypertherm Powermax 105) were protected from exposure to UV light and against radiant energy by enclosing the operation with noncombustible or flameproof screens or shields.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Quality Fabrication & Machine Works, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343833430.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.