ENID, OK ·
OSHA Inspection: ELITE INFRASTRUCTURE LLC
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of ELITE INFRASTRUCTURE LLC in SEC. 29-T22N-R5W KAPPA SWD, ENID, OK 73701 (NAICS 213112). OSHA activity number 343836565.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELITE INFRASTRUCTURE LLC
- Site address
- SEC. 29-T22N-R5W KAPPA SWD
- City
- ENID
- State
- OK
- ZIP
- 73701
- Mailing
- 715 GLENVILLE DRIVE SUITE 430, RICHARDSON, TX 75081
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1200 E01 I
- Issued
- Aug 23, 2019
- Abate by
- Sep 17, 2019
- Penalty
- Initial $5,304 · Current $5,304
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present using an identity that was referenced on the appropriate safety data sheet (Construction Reference 1926.59): a. On or about March 4, 2019, at the tank battery, where ventilation pipe work was being done by employees, the hazard communication program did not include a list of the hazardous chemicals known to be present which included but were not limited to the following: Crude oil (flammable) in oil and gas production water Fiberglass (irritant) SWS-9115 (oxidizer, corrosive) DS8014 Part A (irritant) DS8014 Part B (corrosive) Propane (flammable) Subcontractor employees and employees were exposed to hazardous chemicals during ventilation pipe work at the gun barrel tanks and when responding to spills of produced water that contained crude oil.
Recent events (2)
- · I (O) $5304
- · Z (S) $5304
1910.1200 F06 II
- Issued
- Aug 23, 2019
- Abate by
- Sep 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical (Construction Reference 1926.59): a. On or about March 4, 2019, at the tank battery, two gun barrel tanks, two produce water storage tanks, and two crude oil storage tanks were not labeled, tagged or marked with either the information specified under paragraphs (f)(1)(i) through (v) of this section for labels on shipped containers; or, product identifier and words, pictures, symbols, or combination thereof, which would have provided at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to subcontractor employees and employees under the hazard communication program, would have provided subcontractor employees and employees with the specific information regarding the physical and health hazards of the hazardous chemicals which included but were not limited to crude oil (flammable liquid). Subcontractor employees and employees were exposed to hazardous chemicals during ventilation pipe work at the gun barrel tanks and when responding to spills of produced water that contained crude oil.
Recent events (2)
- · I (O) $0
- · Z (S) $0
1910.1200 G08
- Issued
- Aug 23, 2019
- Abate by
- Sep 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s) (Construction Reference 1926.59): a. On or about March 4, 2019, at the tank battery, copies of the required safety data sheets were not maintained and safety data sheets were not readily accessible during each work shift to employees when they were in their work area for each hazardous chemical known to be present which included but were not limited to the following: Crude oil (flammable liquid) in oil and gas production water Fiberglass (irritant) SWS-9115 (oxidizer, corrosive) DS8014 Part A (irritant) DS8014 Part B (corrosive) Subcontractor employees worked at storage and gun barrel tanks to install ventilation piping which exposed them to hazardous chemicals. Employees were exposed to hazardous chemicals when responding to spills of produced water that contained crude oil.
Recent events (2)
- · I (O) $0
- · Z (S) $0
More inspections in this industry (NAICS 213112)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343836565.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.