OSHA Inspection: VALLEY ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VALLEY ROOFING, LLC in 6325 ESTE AVE, CINCINNATI, OH 45232 (NAICS 238160). OSHA activity number 343841722.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Valley Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for Valley Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VALLEY ROOFING, LLC
Site address
6325 ESTE AVE
City
CINCINNATI
State
OH
ZIP
45232
Mailing
7450 INDUSTRIAL ROAD, FLORENCE, KY 41042
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
41
Ownership type
A

3 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 5 instances 3 exposed
Issued
Jun 13, 2019
Abate by
Jul 10, 2019
Penalty
Initial $9,282 · Current $4,600 Reduced
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.    On March 11, 2019, there were no frequent and regular inspections being performed by a competent person in that:    (a) a personal fall arrest system was being used by an employee 21 feet away from its anchorage at a fall height less than 13 feet from the roof edge, allowing the employee to swing fall into the ground below      (b) one in-use self-retracting lifeline being used as a fixed foot-level anchorage was observed lying on its side on the roof structure, adversely affecting total fall clearance    (c) one employee was performing roofing work at the unprotected edge while wearing a harness that did not have the chest straps attached and was not tied off     (d) one employee was observed walking the length of the roof structure with unprotected sides or edges, which was estimated at 75 feet long, while wearing a harness and not tied off     (e) one reusable roof anchor installed on the south end of the roof structure was observed with only one screw attached    (f) two synthetic web sling anchorages on the north end of the upper roof structure were observed wrapped around the sharp edges of a concrete roof structure without sling protection (to prevent scuffing or abrasion due to friction)
Recent events (2)
  • — I (S) $4600
  • — Z (S) $9282

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 13, 2019
Penalty
Initial $9,282 · Current $4,600 Reduced
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    On Mar. 11, 2019, located on the southeast side of a commercial structure, employees were working from a low-slope roof with unprotected sides and edges while not utilizing a fall protection system. Potential fall heights were measured to be greater than 12 feet above the ground below.
Recent events (2)
  • — I (S) $4600
  • — Z (S) $9282

1926.502 D16 III

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 13, 2019
Penalty
Initial $9,282 · Current $0 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, shall:  be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;    On Mar. 11, 2019, located on the southeast side of a commercial low-slope roof structure, an employee using a shock-absorbing personal fall arrest system with self-retracting lifeline was performing work while positioned 21 feet away from the fixed foot-level anchorage. The employee was exposed to a fall of approximately 13 feet and the hazard of contact with the ground below.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9282

View Valley Roofing, LLC's full OSHA safety record →