Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: ANGEL COLESIO

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ANGEL COLESIO in 4827 DODGE ST, OMAHA, NE 68132 (NAICS 238160). OSHA activity number 343845020.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Angel Colesio for free Get an email when a new federal OSHA severe-injury report for Angel Colesio is published. One employer, no account, unsubscribe in one click.
Establishment
ANGEL COLESIO
Site address
4827 DODGE ST
City
OMAHA
State
NE
ZIP
68132
Mailing
6201 S 41ST ST, OMAHA, NE 68107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 2, 2019
Abate by
Sep 13, 2019
Penalty
Initial $3,978 · Current $3,000 Reduced
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    The employer is failing to protect employees from electrical hazards while operating an aerial lift near energized power lines.  This was most recently documented at 4827 Dodge St, Omaha, Nebraska on March 11, 2019 when an employee was operating an aerial lift in close proximity to energized electrical wires.  The employee received severe electrical burns after making contact with the wires.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3978

1926.454 A

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 2, 2019
Abate by
Sep 13, 2019
Penalty
Initial $3,978 · Current $3,000 Reduced
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:    The employer is failing to protect employees from the hazards associated with working from an elevated aerial boom lift.  This was most recently documented at 4827 Dodge St, Omaha, Nebraska on March 11, 2019 when an employee was operating an aerial boom lift and he had not received training to recognize the hazards associated with this type of activity.  The employee received severe injuries after contacting energized electrical wires.
Recent events (2)
  • · I (S) $3000
  • · Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343845020.