Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOBILE PIPE & WELDING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MOBILE PIPE & WELDING, INC. in 670 SCHILLINGER RD N, MOBILE, AL 36608 (NAICS 237110). OSHA activity number 343845186.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mobile Pipe & Welding, INC. — free Get an email when a new federal OSHA severe-injury report for Mobile Pipe & Welding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
670 SCHILLINGER RD N
City
MOBILE
State
AL
ZIP
36608
Mailing
8305 ZEIGLER BLVD., MOBILE, AL 36608
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
24
Ownership type
A

3 citations on file for this inspection.

1926.652 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Mar 27, 2019
Abate by
Apr 8, 2019
Penalty
Initial $3,789 · Current $2,700 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 paragraph (b) or (c) of this section.   a) 670 Schillinger Rd N; On or about March 12, 2019 the employer exposed employees to cave-in hazards in that employees were allowed to work inside of a trench measuring 7 feet 1 inch deep, 8 feet 9 inch to 11 feet 6 inch wide, and 43 feet in length that was dug in class "b" soil. The employer had not complied with the standard in that employees were not protected from cave-ins by an adequate protective system.  b) 675 Schillinger Rd N; On or about March 12, 2019 the employer exposed employees to cave-in hazards in that employees were allowed to work inside of a trench measuring 6 feet deep, estimated 4 to 10 feet wide, and estimated 15 feet in length that was dug in class "b" soil. The employer had not complied with the standard in that employees were not protected from cave-ins by an adequate protective system.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3789

1926.651 B04

Other-than-serious 2 instances 4 exposed
Issued
Mar 27, 2019
Abate by
Apr 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees:  a) 670 Schillinger Rd N; On or about March 12, 2019 the employer failed to ensure a natural gas pipeline having an unsupported span of approximately 6 feet passing through the excavation was supported to prevent it becoming a hazard to the employees working in the trench.    b) 675 Schillinger Rd N; On or about March 12, 2019 the employer failed to ensure a natural gas pipeline having an unprotected span of approximately 4 feet passing through the excavation was protected to prevent it becoming a hazard to the employees working in the trench.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.651 G01 I

Other-than-serious 2 instances 4 exposed
Issued
Mar 27, 2019
Abate by
Apr 8, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.651(g)(1)(i): Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth.  (a) 670 Schillinger Rd N; On or about March 12, 2019 The atmosphere was not tested where the trench was located near a location flammable material (Gasoline Service Station) is stored underground and a natural gas line passes trough the excavation before employee(s) entered an excavation where oxygen deficiency or a hazardous atmosphere existed or could have reasonably been expected to exist as required.  b) 675 Schillinger Rd N; On or about March 12, 2019 The atmosphere was not tested where the trench was located near a location flammable material (Gasoline Service Station) is stored underground and a natural gas line passes trough the excavation before employee(s) entered an excavation where oxygen deficiency or a hazardous atmosphere existed or could have reasonably been expected to exist as required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Mobile Pipe & Welding, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343845186.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.