Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: ADAMS FINE CABINETRY, INC.

Follow-up inspection · Health discipline

On , OSHA opened a follow-up health inspection of ADAMS FINE CABINETRY, INC. in 1390 LAMAR ST, LAKEWOOD, CO 80214 (NAICS 337110). OSHA activity number 343847497.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Adams Fine Cabinetry, INC. for free Get an email when a new federal OSHA severe-injury report for Adams Fine Cabinetry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1390 LAMAR ST
City
LAKEWOOD
State
CO
ZIP
80214
Mailing
1390 LAMAR ST, LAKEWOOD, CO 80214
Inspection type
Follow-up (F)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
6
Ownership type
Private (A)

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 21, 2019
Abate by
May 16, 2019
Penalty
Initial $3,410 · Current $852 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) On or about February 1, 2019, and at times prior, the employer did not establish and implement a respiratory protection program for employees voluntarily utilizing tight-fitting respirators and filtering facepieces for tasks such as finishing and sanding operations.     T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134 Respiratory protection, which was contained in OSHA inspection number 1290748, citation number 1, item number 1a and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • · I (S) $852
  • · Z (R) $3410

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Mar 21, 2019
Abate by
May 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    (a) On or about February 1, 2019, and at times prior, the employer did not ensure that employees utilizing tight-fitting respirators were medically evaluated prior to usage.    T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134 Respiratory protection, which was contained in OSHA inspection number 1290748, citation number 1, item number 1b and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • · I (S) $0
  • · Z (R) $0

1910.134 K06

Serious Gravity 1 1 instance 6 exposed
Issued
Mar 21, 2019
Abate by
May 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:    (a) On or about February 1, 2019, and at times prior, the employer did not provide information found in Appendix D to employees who voluntarily wore respirators such as 3M 6502 tight-fitting half-face respirators and filtering facepieces.     T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.134 Respiratory protection, which was contained in OSHA inspection number 1290748, citation number 1, item number 1d and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • · I (S) $0
  • · Z (R) $0

1910.303 G01

Other-than-serious 1 instance 6 exposed
Issued
Mar 21, 2019
Penalty
Initial $212 · Current $0 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a) On or about February 1, 2019, and at times prior, the employer did not ensure that employees were protected from electrical hazards by ensuring necessary access to electrical panels in the shop. They were blocked from access by wood working machinery, such as a Delta Shaper.     T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.303 General electrical requirements, which was contained in OSHA inspection number 1290748, citation number 2, item number 3 and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (See Certification of Corrective Action Worksheet).
Recent events (2)
  • · I (O) $0
  • · Z (R) $212

1910.1200 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 21, 2019
Abate by
May 16, 2019
Penalty
Initial $4,546 · Current $1,138 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a) On or about February 1, 2019, and at times prior, the employer did not ensure that a hazard communication program was available and implemented for employees required to use hazardous chemicals during finishing operations such as but not limited to Sher-Wood PreCat Primer Surfacer, which is highly flammable, may cause serious eye damage, and may cause cancer.    T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200 Hazard communication, which was contained in OSHA inspection number 1290748, citation number 1, item number 4a and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • · I (S) $1138
  • · Z (R) $4546

1910.1200 G08

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 21, 2019
Abate by
May 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s):    (a) On or about February 1, 2019, and at times prior, the employer did not ensure that copies of safety data sheets were maintained for hazardous chemicals used during finishing and manufacturing operations such as but not limited to Sher-Wood PreCat Primer Surfacer, which is highly flammable, may cause serious eye damage, and may cause cancer..    T&G Plus 6 LLC, dba Adams Custom Cabinetry, now Adams Fine Cabinetry, Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200 Hazard communication, which was contained in OSHA inspection number 1290748, citation number 1, item number 4c and was affirmed as a final order on June 21, 2018, with respect to a workplace located at 1390 Lamar St., Lakewood, CO 80214.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • · I (S) $0
  • · Z (R) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343847497.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.