SOUTH HADLEY, MA —
OSHA Inspection: TECH FAB, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TECH FAB, INC. in 1 W MAIN ST, SOUTH HADLEY, MA 01075 (NAICS 332999). OSHA activity number 343848206.
Where did this inspection happen?
- Establishment
- TECH FAB, INC.
- Site address
- 1 W MAIN ST
- City
- SOUTH HADLEY
- State
- MA
- ZIP
- 01075
- Mailing
- 1 W MAIN ST, SOUTH HADLEY, MA 01075
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 18
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $5304.00 · Current $3713.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: 1 West Main St, South Hadley MA On March 13, 2019 at the opening of the inspection, the employer had not implemented an energy control program to protect employees who maintained, cleaned, and set up metal working machines. There were no written energy control procedures in use for the press brakes or other multi-energy source machines. Employees received no training on company energy control procedures and the employer did not coordinate energy control procedures with outside repair contractors. The employer had not performed periodic inspections of in-process energy control operations to ensure employee adherence to the written procedures and did not perform a review, between the inspector and each employee of that employee's responsibilities under each energy control procedure.
Recent events (2)
- — I (S) $3712.8
- — Z (S) $5304
More inspections in this industry (NAICS 332999)
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
AITKIN, MN—2026-07-01
111512 - TEEMARK MANUFACTURING INC
SOUTH EL MONTE, CA—2026-06-29
VAGA INDUSTRIES
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343848206.