BOLINGBROOK, IL —
OSHA Inspection: FAIRRINGTON, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FAIRRINGTON, LLC in 553 S. JOLIET ROAD, BOLINGBROOK, IL 60440 (NAICS 484121). OSHA activity number 343849154.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FAIRRINGTON, LLC
- Site address
- 553 S. JOLIET ROAD
- City
- BOLINGBROOK
- State
- IL
- ZIP
- 60440
- Mailing
- 553 JOLIET ROAD, BOLINGBROOK, IL 60440
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 484121
- Employees
- 119
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 E06 I
- Issued
- Jun 20, 2019
- Abate by
- Jul 17, 2019
- Penalty
- Initial $7,577 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: a) Co-Mail Department - On or about March 13, 2019, the employer failed to take precautions to prevent the ignition of flammable vapors from static discharge when the Bitjet printer head ground wires on print lines 2, 3, and 4 were disconnected. The ungrounded printing equipment thereby exposed employees to injuries associated with fire.
Recent events (2)
- — I (S) $5000
- — Z (S) $7577
1910.147 C04 I
- Issued
- Jun 20, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $13,260 · Current $10,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Co-Mail Department - On or about March 25, 2019, the employer failed to ensure an energy control procedure was developed and documented for the control of hazardous energy when an employee was engaged in maintenance tasks, such as lubricating and adjusting the gear tension on the Line 2 Hytrol Conveyor. The employee was thereby exposed to hazards associated with the unexpected energization and/or startup of the equipment.
Recent events (2)
- — I (S) $10000
- — Z (S) $13260
1910.147 C04 II
- Issued
- Jun 20, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Co-Mail Department - On March 13, 2019, the employer failed to develop procedures which outlined the scope, purpose, authorization, rules, and techniques for controlling hazardous energy while performing service and maintenance on the Line 3 Goss Loudon Stacker. An employee was thereby exposed to the unexpected energization and/or startup of the equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D
- Issued
- Jun 20, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a) Co-Mail Department, Line 3 - On or about March 13, 2019, employees were exposed to machine hazards associated with moving parts when unjamming the Goss Loudon Stacker. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from servicing hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $13260
1910.147 C06 I
- Issued
- Jun 20, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $7,577 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer failed to conduct an annual periodic inspection of the energy control procedure. a) Co-Mail Department - On or about March 13, 2019, the employer failed to ensure employees who perform service and/or maintenance on equipment for Lines 2, 3 and 4 participated in an annual periodic inspection of the energy control procedure. Employees were thereby exposed to the unexpected energization and/or startup of the equipment.
Recent events (2)
- — I (S) $5000
- — Z (S) $7577
1910.147 C07 I A
- Issued
- Jun 20, 2019
- Abate by
- Aug 7, 2019
- Penalty
- Initial $13,260 · Current $10,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) Co-Mail Department - On or about March 13, 2019, the employer failed to ensure machine operators and maintenance employees who perform service and/or maintenance on equipment for Lines 2, 3 and 4 received training in the energy control program, and recognition of applicable hazardous energy sources, the types and magnitude of the energy available in the workplace and the methods and means necessary for energy isolation and control. The employees were thereby exposed to the unexpected energization and/or startup of the equipment.
Recent events (2)
- — I (S) $10000
- — Z (S) $13260
More inspections at Fairrington, LLC